74
•
VACON
T
ECHNICAL
DATA
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
11
11. TECHNICAL DATA
11.1 Vacon 10 technical data
Mains connec-
tion
Input voltage U
in
115 V, -15%...+10% 1~
208…240 V, -15%...+10% 1~
208…240 V, -15%...+10% 3~
380 - 480 V, -15%...+10% 3~
600 V, -15%...+10% 3~
Input frequency
45…66 Hz
Connection to mains
Once per minute or less (normal case)
Supply network
Networks
Vacon 10 (400 V) cannot be used with networks that
have a phase to ground
Short circuit current
Maximum short circuit current has to be < 50 kA.
Motor connec-
tion
Output voltage
0 - U
in
Output current
Continuous rated current I
N
at ambient tempera-
ture max. +50 ºC (depends on the unit size), over-
load
1.5 x I
N
max. 1 min / 10 min
Starting current /
torque
Current 2 x I
N
for 2 sec in every 20 sec period.
Torque depends on motor
Output frequency
0…320 Hz
Frequency resolution 0,01 Hz
Control charac-
teristics
Control method
Frequency Control U / f
Open Loop Sensorless Vector Control
Switching frequency
1...16 kHz; Factory default 4 kHz
Frequency reference
Resolution 0.01 Hz
Field weakening point 30…320 Hz
Acceleration time
0.1…3000 sec
Deceleration time
0.1…3000 sec
Braking torque
100%*T
N
with brake option (only for 400 V > 1.5 kW)
30%*T
N
without brake option
Table 11.1: Vacon 10 technical data