Vacmaster VQ607SFD Operator'S Manual Download Page 4

 
 

This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only 
identical replacements parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacs before 
servicing.  Use this Wet/Dry Vac as described in this manual.  Observe the following warnings that appear 
on the motor housing of your Wet/Dry Vac. 

 

DOUBLE INSULATED - GROUNDING NOT REQUIRED - WHEN SERVICING USE ONLY

 

IDENTICAL REPLACEMENT PARTS.

 

 

WARNING

: TO REDUCE THE RISK OF ELECTRIC SHOCK-DO NOT EXPOSE TO RAIN.  STORE 

INDOORS.

 

 

WARNING

:  FOR YOUR OWN SAFETY, READ AND UNDERSTAND OPERATOR’S MANUAL. DO NOT 

RUN UNATTENDED.  DO NOT PICK UP HOT ASHES, COALS, TOXIC, FLAMMABLE OR OTHER 
HAZARDOUS MATERIALS, DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS.

 

CAUTION:

 

• Do not vacuum drywall dust or fireplace soot or ash with standard Wet/Dry filter. This is a very fine dust   

 

  which will not be captured by the filter and may cause damage to motor.  When vacuuming fine dust use a  

 

  fine dust filter (sold separately).

 

WARNING

:  

SERVICING OF DOUBLE-INSULATED WET/DRY VACUUMM

 

WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE PROVIDED 
INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED ON A DOUBLE-INSULATED 
APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED. SERVICING A DOUBLE 
INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM, 
AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL. REPLACEMENT PARTS FOR 
A DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE. 
YOUR DOUBLE-

INSULATED WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ 

AND THE SYMBOL         (SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE 
APPLIANCE.

 

 
• To reduce the risk of electric shock-unplug before cleaning or servicing.

 

• DO NOT

 

use without filters in place.

 

CAUTION

: TO REDUCE THE RISK OF INJURY FROM MOVING PARTS- UNPLUG BEFORE 

SERVICING. 

 

 
 
 
When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required 
A.W.G. wire size.  Use only a 3-wire extension cord which has a 3-prong grounding type plug and 3-hole 
receptacles which accept the tool’s plug.  Before using the vacuum cleaner, make sure the power cord and 
extension cord are in good working conditions.  Make repairs or replacements before using the vacuum 
cleaner.  Only use extension cords that are rated for outdoor use. 
 

 
 
 
 
 
 
 
 

 

Length of Extension Cord 

110V-120V 

25 Feet 

7.5 Meter 

50 Feet   

15.25 Meters 

100 Feet 

30.5 Meters 

150 Feet  

45.7 Meters 

Amps 

A.W.G Wire Size 

0-6 

18 

16 

16 

14 

7-10 

18 

16 

14 

12 

11-12 

16 

16 

14 

12 

13-16 

14 

12 

Not recommended 

EXTENSION CORDS 

DOUBLE INSULATION INSTRUCTIONS  

 

Summary of Contents for VQ607SFD

Page 1: ... Manual 6 Gallon Model No VQ607SFD FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference Part No VQA1BZ 20 60 02 www vacmaster com Cleva North America 44 Parkway Commons Greer SC 29650 ...

Page 2: ...90 day limited warranty will apply Warranty does not apply to defects due to direct or indirect abuse negligence misuse accidents repairs or alterations and lack of maintenance Please keep your receipt as proof of purchase This warranty gives you specific legal rights and you may have other rights which vary form state to state For product service call Customer Service at 866 384 8432 Warranty Saf...

Page 3: ... not working as it should has missing parts has been dropped damaged left outdoors or dropped into water return it to a service center Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run Wet Dry Vac over cord Do not handle plug or the Wet Dry Vac with wet hands To reduce the risk of health hazards from vapors or dusts do not va...

Page 4: ...ULATED APPLIANCE NOR SHOULD A MEANS FOR GROUNDING BE ADDED SERVICING A DOUBLE INSULATED WET DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL REPLACEMENT PARTS FOR A DOUBLE INSULATED WET DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE YOUR DOUBLE INSULATED WET DRY VAC IS MARKED WITH THE WORDS DOUBLE INSULATED AND THE SYMBOL S...

Page 5: ...n Wands D 2 in 1 Utility Nozzle E Crevice Tool F Multi Surface Floor Nozzle G Round Dust Brush H Cartridge Filter I Filter Retainer J Foam Sleeve Filter K Collection Bag L Feet With Casters M 6 Screws Bag N Handle O Operator s Manual UNPACKING AND CHECKING CARTON CONTENTS 1 1 2 1 1 1 1 1 1 1 1 4 1 1 1 NOTE The hose and accessories for this vacuum are 1 25 inch diameter ...

Page 6: ...e into the slots located on the top of the power head and secure it with the screws provided Do not over tighten the screw fig 5b 7 Your vacuum comes ready for dry vacuum cleaning with cartridge filter pre installed If cartridge filter is not installed refer to page 10 for filter installation fig 6 7 8 Optional for improved dust filtering fit collection bag onto the tank Fit the flange onto the in...

Page 7: ...S OR DUST DO NOT VACUUM TOXIC MATERIALS CAUTION Do not vacuum drywall dust or fireplace soot or ash with standard Wet Dry filter This is a very fine dust which will not be captured by the filter and may cause damage to motor When vacuuming fine dust use a fine dust filter sold separately WARNING DO NOT PLUG IN POWER CORD TO POWER OUTLET MAKE SURE PLUG IS DISCONNECTED BEFORE CHANGING AND CLEANING F...

Page 8: ...CONNECTED BEFORE CHANGING AND CLEANING FILTERS 1 Verify that the power cord is disconnected from the outlet fig 1 Make sure that the container is clean and free from dust and dirt 2 Remove cartridge filter and collection bag then carefully install the foam sleeve filter over the filter cage and place the power head back on the container fig 2 See filter installing instructions on page 11 DO NOT US...

Page 9: ...OGGLES COMPLYING WITH ANSI Z87 1 OR IN CANADA CSAZ94 3 BEFORE USING BLOWER WARNING KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS WARNING WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED 1 Verify that the power cord is disconnected from the outlet fig 1 2 Make sure the container is empty before using as a blower 3 Remove hose from the vacuum port 4 Insert the large end of the hose into th...

Page 10: ...o pick up dust If the cartridge filter is wet it will clog quickly and be very difficult to clean Handle the filter carefully when removing it for cleaning and replacing it Check the filters for tears or small holes a small hole can let dust pass through and out of the cleaner Do not use a filter with holes or tears replace it immediately WARNING ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BE...

Page 11: ...own position carefully remove foam sleeve filter fig 4 2 Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water fig 5 3 Allow filter to air dry before installing and using again Symptom Possible Causes Corrective Action Vacuum will not operate 1 No power supply 1 Check power supply cord breakers fuses 2 Faulty power cord 2 Unplug and check the power cord If damage...

Page 12: ...12 PARTS LIST EXPLODED VIEW ...