11
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning should not be done indoors in
living areas. For optimal performance a new filter is recommended.
4. Install cleaned or new filter into place as instructed above in steps 2 and 3 of Installing Cartridge Filter.
5. Wet filters should be removed and allowed to air dry for 24 hours before installing onto the filter cage.
Installing Foam Sleeve Filter
1. Verify that the power cord is disconnected from the outlet. (fig.1)
2. Remove power head and place in upside down position. Follow instructions to remove cartridge filter.
3. Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is covered.
(fig.2 & 3)
4. Replace the power head on to the container.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve filter. (fig.4)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water. (fig.5)
3. Allow filter to air dry before installing and using again.
Symptom
Possible Causes
Corrective Action
Vacuum will not operate
1) No power supply.
1) Check power supply
– cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Container full.
3) Empty container.
Dust comes out from motor cover.
1) The cartridge filter or collection
bag is missing or damaged.
1) Attach or replace cartridge filter
or collection bag.
Reduced efficiency and
motor/speed vibration.
1) There is a blockage in the nozzle
or hose, or the container inlet. Or
dust filter blocked by fine dust.
1) Check nozzle, hose and
container inlets for blockage. Take
off the filter and clean it. Or install
new cartridge filter.
TROUBLESHOOTING
INSTALLING & CLEANING FOAM SLEEVE FILTER
WARNING!
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING
Summary of Contents for VQ607SFD
Page 12: ...12 PARTS LIST EXPLODED VIEW ...