background image

VP

230

 Control Panel

1. 

Vacuum Gauge-

 Indicates the vacuum level inside the chamber.

2. 

Function Lights:  

Vacuum -

 Illuminates to adjust vacuum time as well as during 

the vacuum process. During set up, adjust the vacuum time 

using the UP/DOWN Buttons.  

Gas -

 This model does not offer the gas flush option.

 

Sealing -

 Illuminates to adjust vacuum time as well as during 

the sealing process. During set up, adjust the sealing time using 

the UP/DOWN Buttons.  

Cooling -

 Illuminates to adjust vacuum time as well as during 

the cooling process. During set up, adjust the cooling using the 

UP/DOWN buttons. 

3. 

Working Indicator Light -

 Illuminates to indicate the machine is  

in use.

4. 

LED Screen (Time) -

 Displays current function or cycle time, 

measured in seconds.

5. 

STOP Button -

 Press to stop the cycle and immediately seal the 

pouch. This button will only work when the machine is in the  

vacuum process.

6. 

SET Button -

 Press to select the vacuum time, sealing time, or 

cooling time. Use with the UP/DOWN buttons.

7. 

UP/DOWN Buttons -

 Press to increase or decrease vacuum time, 

sealing time, or cooling time.

6

1

4

7

5

2

3

7

VP

230

 Chamber Vacuum Sealer | 

User Guide

ARY, Inc.  |  11880 College Blvd Suite 550 Overland Park, KS 66210 |  www.VacMasterFresh.com  |  800-821-7849

Summary of Contents for VP230

Page 1: ...v2018 08 20 v2018 08 20 P230 V 30 VP P230 V 30 VP VP230 USER GUIDE Chamber Vacuum Sealer...

Page 2: ...ct advantages over non chamber external suction units First a much higher level of vacuum can be achieved which means a longer shelf life for foods that you package Secondly liquids and liquid rich fo...

Page 3: ...be added Adding Oil to Vacuum Pump Turn off and unplug machine to prevent electrocution 1 Using VacMaster approved 10W non detergent vacuum pump oil fill the enclosed plastic oil bottle 2 Locate the...

Page 4: ...sconnect from power supply when not in use before cleaning and before servicing 7 To provide continued protection against risk do not operate any appliance with a damaged supply cord or plug or after...

Page 5: ...e vacuum packaging helps prevent this from occurring Delicate foods can be frozen prior to packaging to protect them from getting crushed by the vacuum Use VacMaster Bone Guards to cover an item s sha...

Page 6: ...here is less air to be removed from the chamber 6 Seal Bar 7 Lid Lock This feature is used to keep the lid closed while the machine is in storage DO NOT USE while the machine is operating 8 Control Pa...

Page 7: ...ling process During set up adjust the cooling using the UP DOWN buttons 3 Working Indicator Light Illuminates to indicate the machine is in use 4 LED Screen Time Displays current function or cycle tim...

Page 8: ...Adjusting the VP230 Timing Controls NOTE All timing adjustments must be made with the lid lock off and the lid open To adjust set the timing controls press the SET button on the control panel until th...

Page 9: ...ime accordingly NOTE The VP230 settings will always default to the most recently used settings on the machine To prolong the life of your seal bar set the cooling time to twice the sealing time TIP NO...

Page 10: ...ir pockets or air leaks If you notice that the product is not vacuum packaged tightly then increase the vacuum time by 5 seconds vacuum and seal again Seal confirmation Inspect the pouch seal A positi...

Page 11: ...n Vacuum pouch loses vacuum after being sealed Sharp items can poke small holes in pouches To prevent this cover sharp edges with VacMaster Bone Guard and vacuum in a new pouch Some fruits and vegetab...

Page 12: ...the lid 2 15 Amp Fuses 2x Can be used for replacing fuses located on the control transformer and the cord receptacle NSF models will have a fuse on the seal transformer 3 Seal Wire Used to replace sea...

Page 13: ...hing or freezing before vacuum packaging helps prevent this from occurring NOTE It is critical that food handling and storage are maintained at low temperatures You can reduce the growth of microorgan...

Page 14: ...200 Lid 1 4 979220 Lid gasket 1 5 978263 Lid gasket 7 ft 6 Lower pressure plate of the organic cover 2 7 Sticker 1 8 979825 Tape top bar 1 roll 9 979451 Top bar 1 979452 Seal Pad 1 14 VP230 Chamber Va...

Page 15: ...y 19 Standard spring washers 2 20 Hex sprocket head cap screw 2 21 Damping spring 2 22 Pressure regulator plate 2 23 Hex nuts Grade C 2 24 Hex socket head cap screw 2 25 979458 Seal Bar Assembly 1 26...

Page 16: ...Name Qty 22 979465 Module power 1 23 979466 Relay control 2 24 Strut torsion spring 1 25 Mount 1 26 979156 Hose solenoid valve for gauge pistons 1 27 979467 Relay timer 1 28 980100 Relay spacer 4 29 9...

Page 17: ...r Pouches 3 Mil 1000 Box 1x 40722 8 X 10 Pouches 3 Mil Flat Vacuum Chamber Pouches 500 Box 1x 30722 8 X 10 Vacuum Chamber Pouches 3 Mil 1000 Box 1x 30614 8 X 10 Vacuum Chamber Pouches 4 Mil 1000 Box 1...

Page 18: ...ze Compatible Bags Pouches 89 lbs 12 x 15 Chamber Vacuum Sealer Pouches Includes 60 assorted 3 Mil Vacuum Chamber Pouches 20 6 X 8 20 8 X 12 and 20 10 X 13 1 Filler Plate Maintenance Kit User s Guide...

Page 19: ...applicable It excludes all other express oral or written warranties and all warranties implied by law with respect to the Goods including any warranties or merchantability or fitness for a particular...

Page 20: ...ll Rights Reserved VacMaster is a trademark or registered trademark of ARY Inc in the United States and other countries P O Box 412888 Kansas City MO 64141 VacMasterFresh com 800 821 7849 A Product of...