TROUBLESHOOTING

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE 

TROUBLESHOOTING.

PROBLEM

POSSIBLE CAUSE

SOLUTION

The wet/dry 

vacuum will not 

operate.

No power supply.

Check the power supply, cord, 

breakers, and fuses.

Faulty power cord.

Unplug and check the power cord.  

If damaged, have it repaired by a 

professional.

Collection tank is full.

Empty the collection tank.

Switch in the wrong position.

Press the ON ‘I’ button on the power 

head.

The dust comes 

out from the 

motor cover.

The reusable cloth filter is missing 

or damaged.

Attach or replace the reusable cloth 

filter.

Reduced 

efficiency and 

motor/speed 

vibration.

There are blockages in the nozzle, 

hose, or the collection tank inlets.

Unplug and check nozzle, hose and 

collection tank inlets for blockages. 

The reusable cloth filter is clogged 

by fine dust.

Take off the filter and clean it or 

install a new reusable cloth filter.

Summary of Contents for VOM205P

Page 1: ...before use Keep this manual for future reference 2 5 Gallon Model No VOM205P Operator s Manual Wet Dry Vacuum Distributed By Cleva North America Inc 601 Regent Park Court Greenville SC 29607 Replacement Filters Accessories available at Vacmaster com ...

Page 2: ...ducing a high quality durable product This Vacmaster product carries a limited two 2 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Please keep your receipt as proof of purchase This warranty gives you specific legal rights which may var...

Page 3: ... rain Store indoors If vacuum is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from heated su...

Page 4: ...AD AND UNDERSTAND THE OPERATOR S MANUAL DO NOT RUN UNATTENDED DO NOT PICK UP HOT ASHES COALS TOXIC FLAMMABLE OR OTHER HAZARDOUS MATERIALS DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS CAUTION DO NOT VACUUM DRYWALL DUST FIREPLACE SOOT OR ASH THIS TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND CAUSE DAMAGE TO MOTOR WARNING WITH A DOUBLE INSULATED WET DRY VACUUM TWO SYSTEMS OF ...

Page 5: ...ore than Not more than 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 Not recommended SYMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product SYMBOL SIGNAL MEANING DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous sit...

Page 6: ...his vacuum are 1 25 3 2 cm diameter G H I J F D C A B E Carton Contents List Key Description Q t y A Vacuum Assembly 1 B Wall Mount Bracket 1 C Hose 1 D Crevice Tool 1 E Utility Nozzle 1 F Reusable Cloth Filter 1 G Foam Wet Filter 1 H Handle 1 I 2 Screws Bag 1 J Operator s Manual 1 Accessory Storage Power Cord Hook Wall Mount Bracket Blower Port Handle Power Head Hose Organization On Off Switch Va...

Page 7: ...le into place Fig 5 6 Your vacuum comes ready for dry vacuum cleaning If the reusable cloth filter is not installed refer to page 13 for installation instructions Fig 6 7 7 For wet vacuum cleaning remove the reusable cloth filter and install the supplied foam wet filter See page 13 for the foam wet filter installation instructions Fig 8 Tools Required for Assembly Philips Head Screwdriver Helpful ...

Page 8: ...mpty the collection tank before mounting the vacuum on the wall 11 Make sure the bracket is level and mark the hole locations Make1 8 inch diameter pilot hole in each marked location Align the two screw holes so that they are over a stud and secure the wall mount bracket to the wall stud with the two screws provided Fig 13 12 Place the wet and dry vacuum cleaner into the wall mount bracket Fig 14 ...

Page 9: ... on by flipping the switch to the I ON position and begin vacuuming Fig 8 8 Once you have completed vacuuming flip the switch to the O OFF position and unplug the power cord from the outlet O OFF I ON DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING 8 8 7 2 3 4 5 6 WARNING BE SURE TO READ UNDERSTAND AND APPLY INFORMATION ENTITLED IMPORTANT SAFETY INSTRUCTIONS DO NOT VACUUM IN AREAS WITH F...

Page 10: ... quantities of liquids do not immerse the nozzle completely in the liquid leave a gap at the tip of the nozzle opening to allow air inflow The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity You will notice an increase in motor speed When this happens turn off the machine disconnect from power supply and drain the liquid into...

Page 11: ... onto the hose Fig 3 6 Verify that the power switch is in the O OFF position before plugging the power cord into the outlet Plug the power cord into the outlet Fig 4 5 7 Before turning on the vacuum firmly hold onto the loose end of the hose Turn the motor on by flipping the switch to the I ON position Fig 6 8 Once you have completed blowing flip the power switch to the O OFF position and unplug t...

Page 12: ...ed are made of high quality materials designed to stop small dust particles The reusable cloth filter should be used for dry pick up only A dry reusable cloth filter is necessary to pick up dust If the reusable cloth filter is wet it will clog quickly and be very difficult to clean Handle the filter carefully when removing it for cleaning and replacing it Check the filters for tears or small holes...

Page 13: ...ew filter is recommended 3 Use a mild soap and water solution to wash reusable cloth filter and rinse with clean water Fig 5 4 Allow the wet filter to air dry for 24 hours before installing onto the filter cage INSTALLING FOAM WET FILTER 1 Verify that the power cord is disconnected from the outlet Fig 1 2 Remove the power head and place in an upside down position Follow instructions to remove the ...

Page 14: ...s full Empty the collection tank Switch in the wrong position Press the ON I button on the power head The dust comes out from the motor cover The reusable cloth filter is missing or damaged Attach or replace the reusable cloth filter Reduced efficiency and motor speed vibration There are blockages in the nozzle hose or the collection tank inlets Unplug and check nozzle hose and collection tank inl...

Page 15: ...15 EXPLODED VIEW 1 2 3 4 5 6 8 7 10 9 11 12 13 ...

Page 16: ...oat 1 4 551012116 Filter Cage 1 5 Collection Tank 1 6 551012104 Vacuum Port 1 7 551012107 Wall Mount Hook Assembly 1 8 551098111 Wall Mount Bracket Assembly 1 9 551012109 Crevice Tool 1 10 551004113 Utility Nozzle 1 11 551009111 Foam Wet Filter 1 12 551012110 Reusable Cloth Filter 1 13 551012108 Hose 1 ...