11
Installing Foam Wet Filter
1. Verify that the power cord is disconnected from the outlet. (fig.1)
2. Remove power head and place in upside down position. Follow instructions to remove cartridge
filter.
3. Carefully slide foam wet filter down over the filter cage making sure the cage is completely
covered. (fig. 2 & 3)
4. Place the power head onto the collection tank.
Cleaning Foam Wet Filter
1. With the removed power head in an upside down position, carefully remove foam wet filter. (fig.
4)
2. Use a mild soap and water solution to wash foam wet filter and rinse with clean water. (fig. 5)
3. Allow filter to air dry before installing and using again.
WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.
INSTALLING & CLEANING FOAM WET FILTER
TROUBLESHOOTING
Symptom
Possible Causes
Corrective Action
Vacuum will not operate
1) No power supply.
1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the power
cord. If damaged, have it
repaired by a professional.
3) Collection tank full.
3) Empty collection tank.
Dust comes out from motor
cover.
1) The cartridge filter is missing
or damaged.
1) Attach or replace cartridge
filter.
Reduced efficiency and motor/
speed vibration.
1) There is a blockage in the
nozzle, hose, or the collection
tank inlet. The cartridge filter is
clogged by fine dust.
1) Check nozzle, hose and
collection tank inlets for
blockage. Take off the filter
and clean it or install a new
cartridge filter.
2
3
4
5
1
Summary of Contents for VOC1210PF