16
TROUBLESHOOTING
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE
TROUBLESHOOTING.
Cleaning Performance
Vacmaster vacuum cleaners are tested for endurance. If your motor is operating, then the most
likely cause for a loss in suction is a blockage or an opening in the vacuum.
To maintain a high cleaning performance from your machine, it is important to replace or clean
cartridge filters as necessary. Replace full dust collection bags to prevent performance drops. A
performance drop with clean filters can only be caused by a blockage in the tools or the hose.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The appliance does not
work.
No power.
Check the power supply and fuse.
Functional fault in the power cord,
switch, or motor.
Have the damaged part checked by
qualified personnel or contact the
after sales helpline.
Dust is escaping from
the motor cover.
The cartridge filter is missing or
damaged.
Put in a cartridge filter or replace it.
Misuse the foam filter when dry
vacuuming.
Replace the foam filter with the
cartridge filter.
Power tool take-off
socket does not work.
Power tool wattage is not
compatible with the power tool
take-off socket.
Check the wattage is compatible
with the power tool take-off socket.
Incorrect operating mode selected.
Ensure the switch is moved into
position II.
Low suction power and
high operating noise /
vibrations.
Dust bag or disposable bag is full.
Replace the dust bag or disposable
bag.
Suction nozzle, hose, or tank inlet
is blocked.
Check the suction nozzle, hose, and
tank inlet for obstructions.
Cartridge filter is blocked.
Remove the cartridge filter and
clean.
Float valve has closed.
Empty the container of any liquid
waste and ensure the float value
located underneath the filter is able
to move freely.
Power regulator switch is set to
minimum.
Adjust variable power regulator.
The air flow indicator
is still red flashing
after completing filter
cleaning operation.
Suction nozzle, hose, or tank inlet
is blocked.
Check the suction nozzle, hose, and
tank inlet for obstructions.
The cartridge filter has been
contaminated heavily.
Remove and clean or replace with a
new filter.
The container is full.
Empty the container.
Summary of Contents for VMVDK1538SWC-06
Page 1: ...VDK1538SWC 38L 1500W ORIGINAL INSTRUCTIONS...
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...16 15 12 13 14 17 25 31 32 33 34 26 27 28 29 30 20 21 22 23 24 18 6 1 2 4 3 5 10 11 9 8 7 19...
Page 18: ......
Page 19: ......
Page 20: ...1 4 7 2 12 14 8 9 3 11 13 15 16 10 5 6 MAX MIN MAX MIN...
Page 21: ...17 21 18 19 20...
Page 22: ......
Page 23: ...23...