WARNING

: TO REDUCE THE RISK OF ELECTRIC SHOCK-DO NOT EXPOSE TO RAIN.  STORE 

INDOORS.

 

 

WARNING

:  FOR YOUR OWN SAFETY, READ AND UNDERSTAND OPERATOR’S MANUAL.  DO NOT 

RUN UNATTENDED.  DO NOT PICK UP HOT ASHES, COALS, TOXIC, FLAMMABLE OR OTHER 
HAZARDOUS MATERIALS, DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS.

 

 

CAUTION:

 

• 

Do not vacuum drywall dust or fireplace soot or ash with standard Wet/Dry filter.  This is a very fine dust   

 

  which will not be captured by the filter and may cause damage to motor.  When vacuuming fine dust use a  

 

  fine dust filter (sold separately).

 

 

WARNING

:  

SERVICING OF DOUBLE-INSULATED WET/DRY VACUUM 

WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE PROVIDED 
INSTEAD OF GROUNDING.  NO GROUNDING MEANS IS PROVIDED ON A DOUBLE-INSULATED 
APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED.  SERVICING A DOUBLE 
INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM, 
AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL.  REPLACEMENT PARTS FOR A 
DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE. 
YOUR DOUBLE-INSULATED WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ 
AND THE SYMBOL         (SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE APPLIANCE.

 

 

• To reduce the risk of electric shock-unplug before cleaning or servicing.

 

• DO NOT

 

use without filters in place.

 

CAUTION

: TO REDUCE THE RISK OF INJURY FROM MOVING PARTS- UNPLUG BEFORE SERVICING. 

 

 

 

 
 

 

When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required 
A.W.G. wire size.  Before using the cleaner make sure the power cord and extension cord are in good working 
conditions.  Make repairs or replacements before using the vacuum cleaner.  Only use extension cords that 
are rated for outdoor use. 
 
 
   
 

 

 
 
 
 
 
 
 

 
 
 
 
 

 

Length of Extension Cord 

110V-120V 

25 Feet 7.5 

Meter 

50 Feet   

15.25 Meters 

100 Feet 30.5 

Meters 

150 Feet  

45.7 Meters 

Amps A.W.G 

Wire 

Size 

0-6 18  16 

16  14 

7-10 18  16 

14 

12 

11-12 16 

16 

14 

12 

13-16 14 

12 

Not 

recommended 

EXTENSION CORDS

Summary of Contents for VBV809PF

Page 1: ...uum with Detachable Blower 8 Gallon Model No VBV809PF FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www vacmaster com Cleva North America 44 Parkway Commons Greer SC 29650 Part No VR16BZ 20 60 02 ...

Page 2: ...f of purchase This warranty gives you specific legal rights For product service call Customer Service at 866 384 8432 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM Read and understand this owner s manual and all labels on the Wet Dry Vacuum cleaner before operating Safety is a combination of common sense staying alert and knowing how your vacuum works ...

Page 3: ...s materials Do not use this Wet Dry Vac with a torn filter or without the filter installed except when vacuuming liquids as described in the operation section of this manual Do not allow to be used as a toy Close attention is necessary when used by or near children To reduce the risk of injury from accidental starting unplug power cord before changing or cleaning filter Do not leave Wet Dry Vac un...

Page 4: ...E OF THE SYSTEM AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL REPLACEMENT PARTS FOR A DOUBLE INSULATED WET DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE YOUR DOUBLE INSULATED WET DRY VAC IS MARKED WITH THE WORDS DOUBLE INSULATED AND THE SYMBOL SQUARE WITHIN A SQUARE MAY ALSO BE MARKED ON THE APPLIANCE To reduce the risk of electric shock unplug before cleaning or servicing DO NOT...

Page 5: ...C Hose D Blower Wand E Caster Foot W Accessory Storage F Caster G Foam Sleeve Filter H Cartridge Filter I Filter Retainer J Concentrator Nozzle K Crevice Tool L 2 in 1 Floor Brush Squeegee M Adaptor N 4 Screws Bag O Operator s Manual Qty 1 2 1 1 4 4 1 1 1 1 1 1 1 4 1 NOTE The hose and accessories for this vacuum are 1 25 inch 3 2 cm diameter Blower wand and nozzle are 2 5 inch 6 4 cm diameter ...

Page 6: ...ion fig 6 7 7 For wet vacuum cleaning install the supplied foam filter fig 8 See page 11 for filter installation 8 Place the power head back on the container aligning the top section with the latches and snap into place Keep in mind to position the power head so that the blower port is towards the rear fig 9 9 Insert the locking end of the hose into the port of the container and lock in to place f...

Page 7: ...til it stops against the power head fig 2 Your Wet Dry Vac comes with the cartridge filter pre installed if not see page 10 for installation instructions 3 Place filter retainer on top of cartridge filter and tighten down by turning the retainer handle clockwise fig 3 4 Place the power head back on the container aligning the top section with the latches and snap into place fig 4 OPERATING INSTRUCT...

Page 8: ...G 3 Fit the desired nozzle to the vacuum hose fig 3 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 4 5 Turn the motor on by flipping the switch to the I ON position fig 5 6 After use empty the container by unscrewing the drain cap Drain liquids into a suitable receptacle or drain Remember to refit the drain cap to the container after draining c...

Page 9: ...G DEBRIS WARNING WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED 1 Verify that the power cord is disconnected from the outlet fig 1 2 Squeeze the locking lever and lift the detachable blower from the vacuum lid fig 2 3 3 Insert the adaptor into the blowing port and fit it the desired extension wands and or nozzles fig 4 5 4 Ensure the power switch is turned off and plug into the pow...

Page 10: ...and the four screws fig 5 Installing Cartridge Filter 1 Verify that the power cord is disconnected from the outlet 2 Remove lid and power head and place in upside down position 3 Install the cartridge filter over the filter cage with the flat end of the filter towards the vacuum lid Carefully push filter in until it stops against the lid fig 2 3 4 Place filter retainer on top of cartridge filter o...

Page 11: ... foam sleeve filter down over the filter cage making sure the whole cage is covered fig 2 3 4 Replace the power head on to the container Cleaning Foam Sleeve Filter 1 With the removed power head in the upside down position carefully remove foam sleeve filter fig 4 2 Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water fig 5 3 Allow filter to air dry before insta...

Page 12: ...12 EXPLODED VIEW AND PARTS ...

Reviews: