12
1. Verify that the power cord is disconnected from the outlet. (fig. 1)
2. Remove power head and place in upside down position. Follow instructions to remove
cloth filter.
3. Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is
covered. (
fi
g.2 & 3)
4. Replace the power head on to the container.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve
filter. (fig. 4)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water.
(
fi
g. 5)
3. Allow filter to air dry before installing and using again.
Symptom Possible
Causes
Corrective Action
1) No power
supply.
1) Check power supply – cord,
breakers, fuses.
2) Faulty power
cord.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
Vacuum will not operate
3) Container
full.
3) Empty container.
Dust comes out from motor
cover.
1) The cartridge
filter is missing or
damaged.
1) Attach or replace cartridge
filter.
Reduced efficiency and
motor/speed vibration.
1) There is a
blockage in the
nozzle, hose, or
the container
inlet. The
cartridge filter is
clogged by fine
dust.
1) Check nozzle, hose and
container inlets for blockage. Take
off the filter and clean it. Or install a
new cartridge filter.
TROUBLESHOOTING
WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE
TROUBLESHOOTING