![Vacmaster SV10 User Manual Download Page 13](http://html2.mh-extra.com/html/vacmaster/sv10/sv10_user-manual_3119694013.webp)
13
ARY, Inc. | 5200 W 110th Street Suite 200, Overland Park, KS 66211 | www.VacMasterFresh.com | 800-821-7849
SV
5
Sous Vide Immersion Circulator |
User Guide
Always clean and dry your VacMaster
®
SV10 immersion circulator
before storing. It is important to protect it from contact with objects or
equipment that could damage the digital control panel.
1.
Routine Cleaning:
▫
Unplug circulator from electrical outlet. Warning: To avoid
the potential of injury or burns, allow the circulator to cool
to room temperature before removing from water tank.
▫
Keeping the unit upright, wipe the housing clean and dry
with damp cloth.
Do not use abrasive cleaners.
WARNING:
Never immerse the SV10 circulator controls or control
panel in water or other liquids or place it under running water.
DO NOT clean in a dishwasher.
2.
Cleaning Pump Filter:
▫
To minimize water contaminants and scale from entering
and damaging the circulating pump, the SV10 pump
includes an easy-to-clean pump filter. Simply remove and
clean with a soft brush, removing any lodged particles.
DO NOT use abrasive pads or hard tools to remove trapped
debris. Once clean, reinstall the pump filter. Inspect pump filter
periodically.
3.
Mineral or Water Scale Deposits:
▫
Depending on the frequency of use and your water
hardness, minerals and scale may build up on your
circulator’s heater, pump and other components. After
20
uses or 100 hours of use, use your water tank to run the
circulator in either a 15% white vinegar in water solution or
a 10% food safe calcium & lime remover in water solution
at 80
º
C or 176
º
F for 3 hours or until minerals or scale is
removed. Wipe clean and dry throughly when done.