ENG
LISH
75
DISPLAY
DATA
DESCRIPTION
DEFAULT
MEMO
DATA
LUCi
Courtesy lights
CiCL
t.LUC
- Timed function (from 0 to 20’)
no
- Function deactivated
CiCL
- On for the entire duration of the cycle
AUS
Auxiliary channel
Mon
tiM
- Timed function (from 0 to 20’)
biSt
- Bistable operation
Mon
- Monostable operation
SPiA
Low voltage output setting
no
no
- Not used
FLSh
- Flashing function
W.L.
- Warning light function
LP.PA
no / Si
Flashing unit paused
no
Strt
Start inputs
StAn
no
- Inputs from terminal board disabled
StAn
- Standard operation
AP.CH
- Separate opening and closing commands
PrES
- Man-present operation
oroL
- Timer operation
StoP
STOP input
no
no
- The input is disabled: the STOP command is not received
invE
- The STOP command stops the gate: The next START inverts the direction
ProS
- The STOP command stops the gate: The next START does not invert the direction
Foto
Exterior photocell input
CFCh
CFCh
- Functions as an active photocell during closure and with the gate stopped
no
- Disabled
Ch
- Only functions as an active photocell during closure
Fot.i
Interior photocell input
no
APCh
- Functions as an active photocell during opening and closure
no
- Disabled
Ft.tE
Si / no
Photocell testing
Si
CoS1
Edge 1 input (fixed edge)
no
no
- Input inactive
AP
- Input only active during opening
APCH
- Input active during opening and closing
CoS2
Edge 2 input (mobile edge)
no
no
- Input inactive
CH
- Input only active during closing
APCH
- Input active during opening and closing
Co.tE
Safety edge operational testing
no
no
- Test disabled
Foto
- Test enabled for optical edges
rESi
- Test enabled for resistive rubber edges
FinE
End programming.
no
no
- Do not exit the programming menu
Si
- Exit from the programming menu, storing the parameters set