CONFIGURING THE EASY CONTROL UNIT TO RECOGNISE THE WES-EASY SYSTEM
The WES-EASY device communicates the status of safety devices to the main control unit as if they were connected to the terminal board.
Connection of a device by means of the WES-EASY replaces the traditional connection using the terminal board.
So, if the WES-EASY base unit is associated with a photocell, the photocell input on the terminal board should not be used,
the same also applies for safety edges.
Depending on the type of safety device being monitored, the EASY control unit should be configured in a defined manner.
Refer to the following table to set the EASY control unit correctly.
SAFETY DEVICE
Terminal L5
- PHOTO -
Terminal L6
- EDGE -
Dip-switch 8
- motor/test/error -
Dip-switch 5
- edge -
Edge connected by
WES-EASY
No photocell
Jumper with L8
Not connected
OFF
ON
Cabled photocell
Photocell
Not connected
ON
ON
Photocell
connected by
WES-EASY
No edge
Not connected
Jumper with L8
ON
OFF
Standard edge (N.C. contact)
Not connected
Edge
ON
OFF
Resistive / optical edge
Not connected
Edge
ON
ON