13.1 - AUTOMATIC LEARNING OF THE RUN LIMITS
m
CAUTION: to perform the self-learning procedure it is necessary to disable the ADI interface by means of the menu i.Adi .
If some safeties are controlled by means of the ADI module, they will not be active during the self-teaching stage.
5.
Adjust the limit switch cams in the maximum opening and closing positions.
6.
The display shows the control panel and the automatic learning procedure of the run limits starts:
6.1
The door is closed until it comes into contact with the stopper, until it reaches the closing limit switch or until
the UP button is pressed
6.2
The door is opened until it comes into contact with the stopper, until it reaches the opening limit switch or until
the UP button is pressed
6.3
The door is closed until it comes into contact with the stopper, until it reaches the closing limit switch or until
the UP button is pressed
7.
The display shows the recommended value for the obstacle sensor. If no operations are performed for 20 seconds, the control unit exits
the programming phase, without saving the value recommended.
8.
The recommended value may be modified by pressing the
h
and
i
keys, and pressing the
OK
key confirms the displayed value and the
display shows
SEnS
9.
Press and hold the
i
key until the display shows
FinE
, then press the
OK
key, select the option
Si
and then press the
OK
key to exit
programming mode, storing the value for the sensors.
m
PLEASE NOTE: If the control unit is left to time out from programming mode (1 minute), the obstacle sensor return to
the value that was set prior to performing self-training (according to the default values the sensor is
7.5A
).
On the other hand, the limit switch positions are always stored.
13.2 - MANUAL HANDLING
m
WARNING: when this procedure is activated the safeties are not active.
5.
The display shows
MAn
6.
Press and hold the
h
key to open the door or the
i
button to close the door
7.
Release the button to stop the door
8.
To exit this menu, press
OK
.
NOTE: If the motor is inactive for more than one minute the procedure terminates automatically.
example
Summary of Contents for VEGA-24V
Page 2: ......
Page 17: ...ITALIANO 15...
Page 38: ...ITALIANO 36...
Page 53: ...ENGLISH 51...
Page 74: ...ENGLISH 72...
Page 89: ...FRAN AIS 87...
Page 110: ...FRAN AIS 108...
Page 125: ...ESPA OL 123...
Page 146: ...ESPA OL 144...
Page 147: ......
Page 148: ......