PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED

It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior 
to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural 
modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and 
verify that:
•  Your gate is equipped with a central latch.
•  The gate has no friction points, either during closing or opening.
•  The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.
•  The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the 
 

size of the motor reducer itself.

•  The support on which the automation device will be fixed is solid and durable. 
•  The mains power supply to which the automation device is connected has a dedicated safety earthing system and differential breaker 

with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than or equal to 3 mm).

Warning: The minimum safety level depends on the type of use; please refer to the following outline:

GROUP 1 

- Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this type are gates inside 

business premises, where the sole users are employees, or a part of them who have been suitably informed. 

GROUP 2 

- Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example of this may be a 

company gate that accesses onto a public street, and which is only used by employees.

GROUP 3 

- Anyone can use the automated closure, which is thus located on public land. For example the access gate to a supermarket or 

an office, or a hospital.

PROTECTION A 

- Closure is activated by means of a control button with the person present, i.e. with maintained action.

PROTECTION B 

- With the person present, closure is activated by a command controlled by means of a key-switch or the like, in order to 

prevent use by unauthorised persons.

PROTECTION C 

- Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the impact force must 

fall within a curve established by the regulations.

PROTECTION D 

- Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active on just one side 

or on both sides of the door or gate.

PROTECTION E 

- Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person, and installed in 

such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be active within the entire “danger 
zone” of the gate. The Machinery Directive defines “Danger Zone” as any zone surrounding and/or near machinery where the presence of 
an exposed person constitutes a risk to the health and safety of that person.

The risk analysis should take into consideration all danger zones for the automation device, which should be appropriately 
protected and marked. 

In a clearly visible area, apply a sign with information identifying the motorised door or gate. 

The installer should provide the user with all the information relating to automatic operation, emergency opening and 
maintenance of the motorised door or gate.

CLOSURE USE TYPE

TYPE OF ACTIVATION 
COMMANDS

GROUP 1

Informed people

(use in private area)

GROUP 2

Informed people

(use in public area)

GROUP 3

Informed people

(unlimited use)

Man-present command

A

B

Not possible

Remote control and closure in 
view (e.g. infrared)

C or E

C or E

C and D or E

Remote control and closure not 
in view (e.g. radio)

C or E

C and D or E

C and D or E

Automatic control 
(e.g. timed closure control)

C and D or E

C and D or E

C and D or E

Summary of Contents for STARK3

Page 1: ...ER CANCELLI A BATTENTE GB IRREVERSIBLE ELECTROMECHANICAL ACTUATOR FOR SWING GATES F OPERATEUR ELECTROMECANIQUE IRREVERSIBLE POUR PORTAILS BATTANTS E OPERADOR ELECTROMEC NICO IRREVERSIBLE PARA CANCELAS...

Page 2: ...820 100 110...

Page 3: ...ecessario individuare ed eliminare il guasto Nel caso di guasto non risolvibile facendo uso delle informazioni riportate nel presente manuale interpellare il servizio di assistenza V2 V2 declina quals...

Page 4: ...ccesso di un supermercato o di un ufficio o di un ospedale PROTEZIONE A La chiusura viene attivata tramite un pulsante di comando con la persona presente cio ad azione mantenuta PROTEZIONE B La chiusu...

Page 5: ...isposizioni delle direttive 2006 42 CE e 89 106 CE conforme ai requisiti essenziali applicabili delle Direttive Direttiva Macchine 2006 42 CE Allegato I Capitolo 1 Direttiva bassa tensione 2014 35 UE...

Page 6: ...i da 20 a 30 metri Alimentazione 230V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 Alimentazione motore 24V 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 Alimentazione motore 230V 4G x 1 5 mm2 4G x 1 5 mm2 4G x 2...

Page 7: ...e verificare che il valore di A permetta il fissaggio della staffa posteriore altrimenti scegliere un altro punto sul grafico 4 Infine per fissare la staffa sull anta portare il pistone al limite dell...

Page 8: ...UN FERMO MECCANICO IN APERTURA ALTEZZA DELLE STAFFE Fissare le staffe con 54 mm di distanza tra i piani d appoggio in modo da ancorare il motoriduttore in posizione perfettamente orizzontale DUE FERMI...

Page 9: ...ntazione La manovra di sblocco stata prevista per l apertura manuale del cancello in caso di mancanza di corrente o di avaria del motore Inserire la chiave nella serratura del cilindro e ruotarla di 9...

Page 10: ...e FIG 6 Allentare la vite del finecorsa meccanico B Portare l anta nella posizione desiderata in completa apertura Posizionare il finecorsa adiacente al perno di scorrimento C facendolo agire da blocc...

Page 11: ...ame In the event of interventions on automatic or differential breakers or fuses it is essential that faults be identified and resolved prior to resetting In the case of faults that cannot be resolved...

Page 12: ...ple the access gate to a supermarket or an office or a hospital PROTECTION A Closure is activated by means of a control button with the person present i e with maintained action PROTECTION B With the...

Page 13: ...TLY COMPLETED MACHINE Declaration in accordance with Directives 2014 35 UE LVD 2014 30 UE EMC 2006 42 CE MD ANNEX II PART B The manufacturer V2 S p A headquarters in Corso Principi di Piemonte 65 1203...

Page 14: ...30 metres Power supply 230V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 24V motor power supply 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 230V motor power supply 4G x 1 5 mm2 4G x 1 5 mm2 4G x 2 5 mm2 Photocel...

Page 15: ...the fixing of the rear bracket before continuing the installation otherwise choose another point on the scheme 4 Finally bring the piston to the limit position FIG 2 but avoiding that the sliding pin...

Page 16: ...ALLATION SCHEMES MECHANICAL LIMIT SWITCH IN OPENING BRACKETS HEIGHT Fix the brackets keeping 54 mm between the surfaces in order tofix the gear motor horizontally FIG 3 TWO MECHANICAL STOPS OPENING AN...

Page 17: ...nnect the power Manual override has been thought for manual opening of the gate in case of power cut or motor breakdown Insert the key in the cylinder lock and turn it of 90 clockwise direction Pull t...

Page 18: ...FIG 6 Twist off the screw of the mechanical stop B or D Move the door to the desired opening closing position Place the mechanical stop next to the sliding pin C Turn the screw tightly Set the gear m...

Page 19: ...ions sur interrupteurs automatiques diff rentiels ou fusibles il est n cessaire de d terminer et d liminer la panne avant de proc der au r tablissement En cas de panne ne pouvant tre r solue en utilis...

Page 20: ...h pital PROTECTION A La fermeture est activ e l aide d un bouton de commande avec la personne pr sente il s agit d une action pr voyant le maintien enfonc du bouton PROTECTION B La fermeture est acti...

Page 21: ...ositions des directives 2006 42 CE et 89 106 CE est conforme exigences essentielles applicables des Directives Directive Machines 2006 42 CE Annexe I Chapitre 1 Directive basse tension 2014 35 UE Dire...

Page 22: ...a 30 metri Alimentation 230V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 Alimentation moteur 24V 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 Alimentation moteur 230V 4G x 1 5 mm2 4G x 1 5 mm2 4G x 2 5 mm2 Phot...

Page 23: ...on v rifier que la valeur de A permette la fixation de la patte de fixation c t autrement choisir un autre point sur le graphique 4 Finalement pour fixer la patte de fixation sur la porte porter le pi...

Page 24: ...E EN OUVERTURE HAUTEUR DES PATTES DE FIXATION Fixer les pataes des fixation avec 54mm de distance entre les plans d appui de fa on ancrer le motor ducteur en position parfaitement horizontale DEUX FIN...

Page 25: ...entuelle La manoeuvre de d blocage a t pr vue pour l ouverture manuelle du portail en cas d absence de courant ou de panne du moteur Ins rez la cl dans la serrure barillet et tournez la 90 dans le sen...

Page 26: ...ement manuel FIG 6 D sserrer la vis des fins de course m caniques B Ouvrir enti rement la porte dans la position souhait e Positionner les fins de course adjacentes au pivot de glissement C en le fais...

Page 27: ...ionar haciendo uso de la informaci n contenida en el presente manual llame al servicio de asistencia de V2 V2 declina cualquier responsabilidad por la inobservancia de las normas de construcci n de bu...

Page 28: ...o Por ejemplo la puerta de acceso de un supermercado o de una oficina o de un hospital PROTECCI N A El cierre es activado mediante un bot n de mando con la persona presente es decir con acci n manteni...

Page 29: ...las directivas 2006 42 CE y 89 106 CE es conforme con los requisitos esenciales aplicables de las Directivas Directiva de M quinas 2006 42 CE Anexo I Cap tulo 1 Directiva de baja tensi n 2014 35 UE Di...

Page 30: ...mm2 Selector con llave 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Banda de seguridad 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 L mpara de se alizaci n 2 x 1 5 mm2 2 x 1 5 mm2 2 x 1 5 mm2 Antena integrada en la l...

Page 31: ...alor E a continuaci n dibuje una l nea horizontal en el gr fico en correspondencia del valor detectado 2 Seleccione un punto en la l nea apenas dibujada teniendo en cuenta el ngulo de abertura adecuad...

Page 32: ...RA MEC NICO EN ABERTURA ALTURA DE LOS SOPORTES Fije los soportes con 54 mm de distancia entre las superficies de apoyo para anclar el motorreductor en una posici nperfectamente horizontal DOS FINES DE...

Page 33: ...La maniobra de desbloqueo se prev para la apertura manual del port n en caso de falta de corriente o de aver a del motor Insertar la llave en dotaci n en el cilindro oportuno y girarla en sentido hor...

Page 34: ...manual FIG 6 Aflote el tornillo del tope mec nico de final de recorrido B Lieve la hoja a la posici n de abertura completa deseada Coloque el tope de final de recorrido adyacente al perno de deslizam...

Page 35: ...ifferentialschalter oder Sicherungen ausgel st werden muss vor deren Wiederherstellung der Schaden gesucht und behoben werden Im Fall eines nach Konsultation des vorliegenden Handbuchs nicht behebbare...

Page 36: ...hem Boden befindet Ein Beispiel sind die Zugangstore zu einem Supermarkt einer Beh rde oder einem Krankenhaus SCHUTZ A Das Schlie en wird mittels Druckknopfbefehl durch die anwesende Person aktiviert...

Page 37: ...wesentlichen anwendbaren Bestimmungen der Richtlinien ist Maschinenrichtlinie 2006 42 EG Anhang I Kapitel 1 Niederspannungsrichtlinie 2014 35 EG Richtlinie ber elektromagnetische Vertr glichkeit 2014...

Page 38: ...rsorgung 230V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 Spannungsversorgung Antriebe 24V 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 Spannungsversorgung Antriebe 230V 4G x 1 5 mm2 4G x 1 5 mm2 4G x 2 5 mm2 Fo...

Page 39: ...3 Stellen Sie sicher dass der Wert A die Befestigung des hinteren B gels gestattet und w hlen Sie anderenfalls einen anderen Punkt auf der Grafik 4 Bringen Sie f r die Befestigung des B gels am Torfl...

Page 40: ...HER ZAUN IN DER FFNUNG H HE DER HALTERUNGEN Befestigen Sie die Halterungen mit einem Abstand von 54 mm zwischen den Auflagefl chen um den Getriebemotor in perfekt horizontaler Position zu verankern ZW...

Page 41: ...rsorgung Das Ausl seman ver wurde f r das manuelle ffnen des Tors bei Stromausfall oder Motorausfall konzipiert Stecken Sie den Schl ssel in das Zylinderschloss und drehen Sie ihn um 90 im Uhrzeigersi...

Page 42: ...t Bringen Sie den Getriebemotor in den Handbetrieb FIG 6 L sen Sie die mechanische Endschalterschraube B Bringen Sie das Blatt vollst ndig in die gew nschte Position Positionieren Sie den Endschalter...

Page 43: ...41...

Page 44: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...

Reviews: