EN
G
LIS
H
11
1. PROGRAMMING CODE
The programming code is the 6 digit combination to be entered
in order to change the keypad settings.
The factory code is 999999.
To guarantee more safety, we suggest customizing the
programming code and keeping the new one in a safe place.
!
PLEASE NOTE: if the PROGRAMMING CODE is
lost/forgotten, it cannot be restored.
The device should be returned to the V2 assistance centre.
Customization of the programming code
OPERATIONS TO BE MADE ON THE KEYPAD
1.
Key in
#
+
PROGRAMMING CODE
+
#
Signalling: 1 BEEP of 1,5 sec. + L1 and L2 on for 1,5 sec.
2.
Key in within a minute the KEY
1
+
#
Signalling: 1 BEEP + L1 on
3.
Repeat the
PROGRAMMING CODE
+
#
Signalling: 1 BEEP of 1 sec. + L1 on
4.
Key in the
NEW PROGRAMMING CODE
+
#
Signalling: 1 BEEP of 1 sec. + L1 on
5.
Repeat the
NEW PROGRAMMING CODE
+
#
Signalling:
-
1 BEEP of 3 sec. + L1 and L2 on if the
operation is correct;
-
short flashes of the LED if incorrect
WARNING:
if the operation has failed (e.g. for having entered
chosen code and confirmation code different one from the other
or for having waited more then 1 minute) the digital selector
goes back to STAND-BY mode keeping the original access code
and it is necessary to start again
WARNING:
in case of loss of the PROGRAMMING CODE, contact
V2 technical service.
2. ACCESS CODE
The access code is the combination to be keyed in to activate the
transmission of the digital code.
The factory code set for the channel 1 is 1111, while the
other channels are disabled.
To enable a channel just set an access code.
The first digit of the code always identifies the channel of
reference and can not be modified. This means that it
won't be possible to give to the channel 1, for instance, an
access code different from 1xxxxxxx, to the channel 2 an
access code different from 2xxxxxxx and so on.
PLEASE NOTE:
To be able to function, each channel should be
memorised in the receiver.
NOTE:
the possibility to use access codes made up by a unique
digit, therefore with the only identification digit of the channel,
makes the digital selector a simple multi channel transmitter, for
which no safety characteristics are required. Pressing the key, the
correspondent channel is started up.
Customization of the access code
OPERATIONS TO BE MADE ON THE KEYPAD
1.
Key in
#
+
PROGRAMMING CODE
+
#
Signalling: 1 BEEP of 1,5 sec. + L1 and L2 on for 1,5 sec.
2.
Key in within a minute the KEY
2
+
#
Signalling: 2 BEEP + L2 on
3.
Key in the
NUMBER OF THE CHOSEN CHANNEL
+
#
Signalling: 1 BEEP of 1 sec. + L2 on
4.
Key in the
NEW ACCESS CODE
+
#
Signalling: 1 BEEP of 1 sec. + L2 on
5.
Repeat the
NEW ACCESS CODE
+
#
Signalling:
-
1 BEEP of 3 sec. + L1 and L2 on if the
operation is correct;
-
short flashes of the LED if incorrect
Disabling a channel
OPERATIONS TO BE MADE ON THE KEYPAD
1.
Key in
#
+
PROGRAMMING CODE
+
#
Signalling: 1 BEEP of 1,5 sec. + L1 and L2 on for 1,5 sec.
2.
Key in within a minute the KEY
2
+
#
Signalling: 2 BEEP + L2 on
3.
Key in the
NUMBER OF THE CHOSEN CHANNEL
+
#
Signalling: 1 BEEP of 1 sec. + L2 on
4.
Key in the KEY
0
+
#
Signalling: 1 BEEP of 1 sec. + L2 on
5.
Repeat the KEY
0
+
#
Signalling:
-
1 BEEP of 3 sec. + L1 and L2 on if the
operation is correct;
-
short flashes of the LED if incorrect
3. WORKING MODE: ROYAL, 53200 or
PERSONAL PASS
Select the working mode according to the kind of remote
controls already used in the system.
OPERATIONS TO BE MADE ON THE KEYPAD
1.
Key in
#
+
PROGRAMMING CODE
+
#
Signalling: 1 BEEP of 1,5 sec. + L1 and L2 on for 1,5 sec.
2.
Key in within a minute the KEY
3
+
#
Signalling: 3 BEEP + L1 and L2 on
3. •
Key in the KEY
1
+
#
to select ROYAL mode
•
Key in the KEY
2
+
#
to select 53200 mode
•
Key in the KEY
3
+
#
to select PERSONAL PASS mode
• Key in the KEY
4
+
#
to select P.PASS mode with
MONOSTABLE operating logic*
Signalling: 1 BEEP of 1 sec.
4.
Repeat to confirm (
1
+
#
or
2
+
#
or
3
+
#
or
4
+
#
)
Signalling:
-
1 BEEP of 3 sec. + L1 and L2 on if the
operation is correct;
-
short flashes of the LED if incorrect
* only for RADIO models
Summary of Contents for Sirmo-Digit Series
Page 2: ...Fig 2 Fig 1...
Page 3: ...Fig 3 Fig 4 Fig 5 Fig 7...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......