V2 LEX-RFO Manual Download Page 11

ENGLISH

- 21 -

PROGRAMMING OF CLOSING LIMIT SWITCH 
OF ROLLING SHUTTER (CLOSED LOUVER 
BLADES)

NOTE: you must have a previously stored transmitter 
available and must proceed with the following points
1.

  Supply power only to the control unit to be programmed

2.

  Activate the ARTEMIS programming

3.

  Press the UP or DOWN keys until the LED 5 lights up with solid 

light and the others flash

4.

  Press and hold down the UP+DOWN keys until the motor 

moves in both directions which confirms it is entering the 
programming phase

5.

  Release the keys, the motor stops

6.

  Bring the roll-up shutter to the LOWER position desired using 

the UP or DOWN keys. To regulate it precisely, press the 
UP+DOWN keys when the motor is close to the end-of-stroke: 
the motor will start to move in jerks 

7.

  Press the STOP button when the desired position is reached 

8.

  To exit the programming mode press the STOP key

PROGRAMMING OF OPENING POSITION OF 
ADJUSTABLE LOUVER BLADES

NOTE: you must have a previously stored transmitter 
available and must proceed with the following points
1.

  Bring the roll-up shutter to the INTERMEDIATE position desired

2.

  Activate the ARTEMIS programming

3.

  Press the UP or DOWN keys until the LED 3 lights up with solid 

light and the others flash

4.

  Press the UP+DOWN keys of the transmitter until the motor 

confirms the storage of the intermediate position moving in 
both directions for 1/2 seconds 

5.

  Using the UP and DOWN buttons, open the louver blades to 

the desired position. To perform a precise adjustment press 
the PROG button when the motor approaches the desired 
position, the motor will begin to move jerkily

6.

  Press the key STOP once reached the required position: the 

motor stops and then proves the correct storage of the end-
of-stroke by moving for 1/2 second first upwards and then 
downwards

7.

  To exit the programming mode press the STOP key

To bring the rolling shutter into the opening position of the 
adjustable louver blades press the STOP button for at least 
3  seconds (with the motor stationary): the louver blades 
moves until it reaches the tracked position.

PROGRAMMING OF OPENING LIMIT SWITCH 
OF THE ROLLING SHUTTER

To set the opening limit switch on a rolling shutter with 
a blockage at the top, you must have a previously stored 
transmitter available and must proceed with the following 
points.
1.

  Supply power only to the control unit to be programmed

2.

  Activate the ARTEMIS programming

3.

  Press the UP or DOWN keys until the LED 3 lights up with solid 

light and the others flash

4.

  Press and hold down the UP+DOWN keys until the motor 

moves in both directions which confirms it is entering the 
programming phase

5.

  Release the keys, the motor stops

6.

  Press the UP key: the roll-up shutter rises at a normal speed

7.

  Once in contact with the upper lock, it stops and memorizes 

the position

8.

  To exit the programming mode press the STOP key

To set the opening limit switch on a rolling shutter without 
blockage at the top, you must have a previously stored 
transmitter available and must proceed with the following 
points.

Repeat points 1,2,3,4,5 previously described

6.

  Bring the roll-up shutter to the upper position desired using 

the UP and DOWN keys. To regulate it precisely, press the 
UP+DOWN key when the motor is close to the end-of-stroke: 
the motor will start to move in jerks

7.

  Press the STOP button when the desired position is reached

8.

  To exit the programming mode press the STOP key

Summary of Contents for LEX-RFO

Page 1: ...USTABLE LOUVER BLADES BUILT IN CONTROL UNIT F MOTOR DUCTEUR TUBULAIRE POUR VOLETS PERSIENN S DE LAMES ORIENTABLES ARMOIRE DE COMMANDE INTEGREE E ROHRMOTOR F R ROLLL DEN MIT SCHWENKBAREN LAMELLEN INTEG...

Page 2: ...it Drehmoment Voor motoren met een koppel tot 30 Nm code 162847 30 Nm code 162829 50 Nm Fig 1 Modello carico coppia velocit alimentazione potenza tempo di funzionamento lunghezza L Model load torque s...

Page 3: ...3 Fig 3 Fig 2...

Page 4: ...3 MARRONE Fase BROWN Phase MARRON phase 4 NERO Pulsante BLACK External switch NOIR touche 5 GIALLO VERDE Terra YELLOW GREEN Ground JAUNE VERT terre E CONEXIONES D ANSCHL SSE NL AANSLUITINGEN 1 WEISS N...

Page 5: ...ng the safety norms in force Only apply to authorized personnel to replace the feeding cable of the motor Do not pierce nor insert screws in the whole length of the motor Avoid any contact of the moto...

Page 6: ...WIRED SWITCH Pressing the external wired switch the control unit has the following functioning logic OPENS a STOPS a CLOSES a STOPS a OPENS FUNCTIONING WITH TRANSMITTERS At each push button pressure...

Page 7: ...nsmitter TX1 until displayed the channel stored by the leds 2 Multichannel transmiter only press several times the key SELC of the new transmitter TX2 until display the channel to be stored by the led...

Page 8: ...then downwards 8 Set to OFF the switch 6 of the transmitter To bring the rolling shutter into the opening position of the adjustable louver blades press the STOP button for at least 3 seconds with the...

Page 9: ...starts to move in one direction Artemis with 2 channels Press the UP DOWN keys of one of the two channels until the motor starts to move in one direction Artemis with 6 channels Select the channel to...

Page 10: ...the programming remains active for 30 seconds during which the LEDs flash Artemis with 2 channels Press the STOP UP DOWN keys of the channel to be programmed until the LEDs light up Release the keys...

Page 11: ...kily 6 Press the key STOP once reached the required position the motor stops and then proves the correct storage of the end of stroke by moving for 1 2 second first upwards and then downwards 7 To exi...

Page 12: ...record remote controls for a new control unit that drives a shutter or a sunshade NOT with casing proceed as follows 1 Power only the control unit to be programmed 2 Press and hold down UP and DOWN un...

Page 13: ...TTERS and start again the above procedure To add other remote controls follow points 6 7 and 8 of the QUICK transmitter recording DELETION OF ALL THE STORED TRANSMITTERS To delete all the transmitters...

Page 14: ...and enter the code 12 11 15 The two highlighted digits indicate the remote control channel recorded in the control unit for channel 1 the digits are 11 for channel 2 the digits are 12 for channel 3 th...

Reviews: