4. Adjusting the sensitivity (default: 4)
This menu allows the sensitivity of the device, when the door encounters an obstacle, to be increased or decreased.
This parameter is already set to a mid value (4) that should be ideal for the majority of installations.
3. Self learning of the forces
Press the
-
key,
the display shows
33
Press the
key:
33
flashes - the door opens
When the door stops, press
the
key to confirm.
Press the
key once more
to continue - the door closes
When the door stops, press the
key to save the settings.
The display shows
33
5. Remote control button selection (default: 2)
This menu allows selection of the button to be used for controlling the automation system. This function may be useful where it is desired
to control several different automation systems using different buttons on the same remote control.
Press the
-
key,
the display shows
55
Press the
key:
22
flashes
to indicate that the 2 key on
the remote control unit
controls this motor
Press the
+
or
–
key
to select the desired key.
Press the
key to save
the settings: the display
shows
55
Press the
-
key,
the display shows
44
Press the key
:
00
flashes
Select the desired level using the
+
and
–
keys
PLEASE NOTE: On completion of the procedure, it is possible to exit the programming procedure, storing the parameters
set: press and hold the
key for 5 seconds until the segments of the display illuminate one at a time until showing
00
PLEASE NOTE: if this parameter is modified, then on completion of programming, it is
necessary to conduct a complete open/close cycle, during which the control unit automatically
conducts a fresh force training operation (during this cycle, the motor works at maximum force,
so particular attention must be paid).
Press the
key to save
the settings: the display
shows
44