E
N
G
L
IS
H
17
SET-UP OF OPERATIONAL
PARAMETERS
JEDI-L is equipped with a practical interface that
allows rapid and simple on-display programming
using four keys:
,
,
+
,
-
.
Preliminary operations:
1.
Move the door so as to hook on the drive
trolley.
2.
Power up the device: the courtesy light comes
on, the control unit emits a BEEP and the
segments of the display are illuminated one at a
time until the display shows
00
.
PLEASE NOTE: if programming is not
completed (by means of function 9.
End programming) the parameters set are lost.
If there is an error in the set parameters, simply
power off the device, restore power and then
repeat the programming operation.
1. Setting the open limit switch
PLEASE NOTE: The open limit switch must be stored prior to the close limit switch. If this
procedure is used erroneously to set the close limit switch, the parameter is NOT stored.
Press the
key for
5 seconds
When the door reaches the
desired position, press the
key to save the settings
The device emits a beep and
the display shows
II
Press the
key:
II
flashes
Press and hold the
+
(the door opens)
or
-
(the door closes)
key to reach the fully open
position
2. Setting the close limit switch
Press the
-
key,
the display shows
22
Press the
key:
22
flashes
Press and hold the
+
(the door opens)
or
-
(the door closes)
key to reach the fully
close position
When the door reaches the
closed position, wait 2
seconds, then press the
key to save the settings