E
N
G
L
IS
H
46
Pd8 FUNCTION TABLE
DISPLAY DATA
DESCRIPTION
DEFAULT
MEMO
DATA
t.AP
0.0" ÷ 2.0'
Gate opening time
15.0"
t.APP
0.0" ÷ t.AP1
Opening time of pedestrian gate
6.0"
t.Ch
0.0" ÷ 2.0'
Gate closing time
16.0"
t.ChP
0.0" ÷ t.Ch
Closing time of pedestrian gate
7.0"
t.PrE
0.5" ÷ 2.0'
Pre-flashing time
1.0"
no
- Pre-flashing disabled (it corresponds to 0)
dir
Gate direction (the direction you see from the inside)
dx
dx
- The gate opens rightwards
Sx
- The gate opens leftwards
Pot
30 ÷ 100%
Motor power
85
SPUn
no/Si
Start off
no
t.P.So
0.5" ÷ 3.0"
Slowed down starting time
1.5"
no
- Slowed down starting disabled
t.raL
0.5" ÷ t.AP
Slow down time
2.0"
no
- Slow down disabled
St.AP
Start in opening
PAUS
no
- Start command is not available
ChiU
- Command close gate
PAUS
- Stop the gate and goes in pause
St.Ch
Start in closing
StoP
Stop
- Start command stop the gate
APEr
- Start command open the gate
St.PA
Start in pause
ChiU
no
- Start command is not available
ChiU
- Start command closes the gate
SPAP
Pedestrian in opening
PAUS
no
- Pedestrian start command is not available
ChiU
- Pedestrian start command closes the gate
PAUS
- Gate goes in pause
Ch.AU
Automatic closing
no
no
- The gate closes after the setup time)
0.5"÷ 20.0'
- The automatic closing is not active (it corresponds to 0)
Ch.tr
Closing after passage
no
no
- Closing after passage disabled
0.5"÷ 20.0'
- Gate stop for a time to be set between 0.5" to 20'
LP.PA
no/Si
Flashlight in pause
no
PA.tr
no/Si
Pause after transit
no