ENGLISH
- 12 -
ELECTRICAL CONNECTIONS
230V
120V
FUNCTION
1
YELLOW - GREEN
GREEN
GND
2
GREY
WHITE
COMMON
3
BLACK
BLACK
CLOSING
4
BROWN
RED
OPENING
EMERGENCY RELEASE
In case of a blackout, the gate can be operated directly from the
motor. Insert the key supplied in the lock, perform 1/2 of a turn.
To restore the automation, simply rotate the key in closed position
and insert the provided plastic cover onto the lock.
m
WARNING: always remember to
connect the earth according to current
standards (EN 60335-1, EN 60204-1).
Avoid tension in the cable during open and
close operations.