E
N
G
L
IS
H
11
ELECTRICAL CONNECTIONS
BLITZ-230V / BLITZ-120V
Rif
.
Left MOTOR (SX)
Right MOTOR (DX)
���
���
GND
GND
���
���
COMMON
COMMON
���
���
OPENING
CLOSING
���
���
CLOSING
OPENING
Rif
.
Left MOTOR (SX)
Right MOTOR (DX)
���
���
OPENING
CLOSING
���
���
CLOSING
OPENING
WARNING: always remember to connect the earth
according to current standards (EN 60335-1, EN 60204-1).
BLITZ-24V
ADJUSTMENT OF STOP ENDS
Opening stop end:
release the actuator and put the door into
its opening position. Adjust the cam (LOWER for the RIGHT
motor and UPPER for the LEFT motor) until the microswitch is
entered (see figure). Then fasten the cam by closing the screw.
Closing stop end:
release the actuator and put the door into its
closing position. Adjust the cam (UPPER for the RIGHT motor and
LOWER for the LEFT motor) until the microswitch is entered.
Then fasten the cam by closing the screw.