background image

ENGLISH

- 4 -

BLINKO is an LED flasher unit for indicating the hazards associated 
with the use of automation devoices for gates, garage doors and 
road barriers; any other use is forbidden and inappropriate.

IMPORTANT WARNING

Warning! The installation of the product has to be made by 
qualified personnel, under the laws and rules in force and 
following the instructions of this handbook. 
It is important to respect the following warnings:
•  Check that the voltage of the product is compatible with the 

one on the clamp of the control unit used for the connection 
of the flashing light.

•  Before making the electrical connections, cut electricity off the 

control unit.

REFERENCE OF MARKING SYMBOLS:
The label affixed to the product bears the following symbols that 
have the following meaning:

  continuous current power supply voltage

  protection against electric shock guaranteed by 

  reinforced 

insulation

TECHNICAL FEATURES

Power supply

24 ÷ 300V 
24 ÷ 230V~ 50/60Hz

Intermittence

automatic

Max working cycle

80%

Protection degree

IP54

Working temperature

-20 ÷ +60 °C

Dimensions

90 x 43 x 36 mm

PRELIMINARY CHECK

•  Check the packaging integrity before opening it and, once 
  open, check the product integrity inside it
•  Check that the place chosen for the installation grant the user 
  total visibility of the flashing light from a long distance
•  Check that the surface chosen for the installation is strong 
  and grant a steady fixing 

m

 ATTENZIONE: WARNING: avoid the surfaces where 

seepage in case of rain is possible

INSTALLATION

1. 

To define the points envisaged for installation, bearing in mind 
that it is necessary to fix the flashing unit onto a flat linear 
surface and that the device may only be installed in a vertical 
position (Fig. 1-2)

3. 

Open the box of the flashing light and use the base to mark 
the fixing holes 

A

 (Picture 1)

4.

  Smash in the pre-breaks for the cables 

B

 and introduce a 

suitable cable gland

5.

  Fix the base

6.

  Connect the flashing light output of the control unit on the 2 

terminals of the flashing light.

m

 

WARNING: use a cable suitable for external use with 

a minimum section of 2x0,5 mm

2

 and a maximum one of 

2x1,5mm

2

7.

  Seal the holes of the plugs with silicone to avoid seepage of 

water inside the device

8.

  Close the box with the special screws

DISPOSAL

As for the installation, the disposal of the product at the end of its 
effective life must be performed by qualified personnel.
This product is made of various types of material, some of which 
can be recycled while others must be disposed of. 
Enquire about the recycling or disposal systems available for this 
product category in compliance with regulations locally in force.

EU DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that BLINKO equipment conforms to the 
essential requirements established in directives:

2014/35/UE low voltage directive
2014/30/EU electromagnetic compatibility directive 
RoHS2 2011/65/EC

Racconigi, 01/06/2015
Legal representative, V2 S.p.A.

Antonio Livio Costamagna

Summary of Contents for BLINKO

Page 1: ...18 BLINKO I LAMPEGGIANTE A LED MULTITENSIONE GB LED FLASHING LIGHT F FEU LED MULTI TENSION E L MPARA DE SE ALIZACI N CON LED MULTITENSI N P PIRILAMPO COM LED MULTITENS O D LED BLINKLICHT NL MULTISPANN...

Page 2: ...Fig 1 Fig 2...

Page 3: ...ssaggio stabile mATTENZIONE evitare piani dove si possano formare depositi di acqua in caso di pioggia INSTALLAZIONE 1 Definire i punti previsti per l installazione tenendo conto che necessario fissar...

Page 4: ...trong and grant a steady fixing mATTENZIONE WARNING avoid the surfaces where seepage in case of rain is possible INSTALLATION 1 To define the points envisaged for installation bearing in mind that it...

Page 5: ...s o des d p ts d eau peuvent se former en cas de pluie INSTALLATION 1 D finir les points pr vus pour l installation en tenant compte qu il est n cessaire de fixer le clignotant sur une surface lin air...

Page 6: ...rme mATENCI N evitar las superficies donde se pueden formar sedimentos de agua en caso de lluvia INSTALACI N 1 Defina los puntos previstos para la instalaci n teniendo en cuenta que es necesario fijar...

Page 7: ...O em tempo de chuva evitar as superf cies onde possa haver infiltra o de guas INSTALA O 1 Definir os pontos previstos para a instala o tendo em conta que necess rio fixar o pisca pisca numa superf ci...

Page 8: ...ammlungen bilden k nnen sind zu vermeiden INSTALLATION 1 Die f r die Installation vorgesehenen Punkte festlegen und dabei ber cksichtigen dass das Blinklicht auf einer geradlinigen und ebenen Fl che b...

Page 9: ...ervlakken waarop bij regen waterplassen gevormd kunnen worden INSTALLATIE 1 Bepaal de punten voor de installatie rekening houdend met het feit dat het knipperlicht op een rechtlijnig en vlak oppervlak...

Page 10: ......

Page 11: ......

Page 12: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...

Reviews: