26
DISPLAY
DATA
DESCRIPTION
DEFAULT
MEMO
DATA
DATA
dEF
no/Si
no
t.AP1
0 ÷ 120 s
22.5
t.AP2
0 ÷ 120 s
22.5
t.APP
0 ÷ t.AP1
6.0
t.Ch1
0 ÷ 120 s
23.5
t.Ch2
0 ÷ 120 s
23.5
t.ChP
0 ÷ t.Ch1
7.0
t.C2P
0 ÷ t.ChP
0.0
r.AP
0 ÷ 120s
1.0
r.Ch
0 ÷ 120s
3.0
t.SEr
0 ÷ 120s
3.0
t.ASE
0 ÷ t.SEr
0.0
t.inv
0 ÷ 120s
0.0
t.PrE
0 ÷ 120s
1.0
t.rAL
0 ÷ 120s
0.0
t.CvE
0 ÷ 120s
0.0
Pot.
30 ÷ 100%
40
SPUn
no/Si
Si
St.AP
PAUS
no
ChiU
PAUS
St.Ch
StoP
Stop
APEr
St.PA
ChiU
no
ChiU
SP.AP
PAUS
no
ChiU
PAUS
Ft.PA
r.PAU
r.PAU
t.PCh
Ch.AU
no
no
t.PAU
LUCi
t.LUC=60s
CiCL
t.LUC
AUS
tiM
biSt
Mon
LP.PA
no/Si
no
In.LP
no/Si
no
OroL
no/Si
no
FUNCTION TABLE PD1
Load V2 ELETTRONICA standard data
Gate 1 opening time
Gate 2 opening time
Opening time of pedestrian gate
Gate 1 closing time
Gate 2 closing time
Closing time of pedestrian gate
Closing time gate 2 during pedestrian cycle
Gate delay during opening
Gate delay during closing
Lock time
Lock advance time
Backlash time
Pre – flashing time
Slowing down time (PD5 only)
Fast closing time after slowing down during closing
Motor power
Star t off
Star t in opening
- Star t command is not available
- Command close gate
- Stop the gate and goes in pause
Star t in closing
- Star t command stop the gate
- Star t command open the gate
Star t in pause
- Star t command is not available
- Star t command closes the gate
Pedestrian in opening
- Pedestrian star t command is not available
- Pedestrian star t command closes the gate
- Gate goes in pause
Photocell in pause
- Pause time recharged
- Gate stop for a time to be set between 0 to 120 s
Automatic closing
- Automatic closing not available
- Reclosing is available, the standstill time is set from 0 to 999 s
Cour tesy Light
- Lights are on trough the whole cycle
- Lights star t time adjustable from 0 to 999 s
- Auxiliar y output
- Timed aux out (from 0 to 999 s)
- Aux out relay with bistable functioning
- Aux out relay with monostable functioning
Flashlight in pause
Flashlight with intermittence
Timer function
Summary of Contents for PD1
Page 2: ...PD1 ISTRUZIONI 1 INSTRUCTIONS 15 NOTICES 29 ANLEITUNGEN 43 INSTRUCCIONES 57 I GB F D E...
Page 16: ...14 NOTE...
Page 30: ...28 NOTE...
Page 44: ...42 NOTA...
Page 58: ...56 BEMERKUNGEN...
Page 72: ...70 NOTA...