ELECTRIC CONNECTIONS TABLE

M1

Incoming switch

M2

Outer sensor of presence

M3 - M6 - M9

Common

M4

Outgoing switch

M5

Inner sensor of presence

M7

Fire alarm switch

M8

Coded input to connect proximity readers or
digital keypads

M10

24VDC for the power supply of the accessories

M11

24VAC for the power supply of the accessories

M12

GND for the power supply of the accessories

C.U. Power

Power supply from network (230V/120V)

W1 - W2

Power supply for the lamps of the lights

Z1

GREEN - inner traffic light

Z2

COMMON - inner traffic light

Z3

RED - inner traffic light

Z4

GREEN - outer traffic light

Z5

COMMON - outer traffic light

Z6

RED - outer traffic light

G1

Antenna shield

G2

Antenna central unit

G3

Common (earth) of the control unit of the gate

G4

START input (N.O.) of the control unit of the gate

G5

START input (N.C.) control unit of the gate

G6 - G7

Warning light of the control unit of the gate

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for City5

Page 1: ...uesto caso a riposo il semaforo verde in entrata e rosso in uscita I veicoli in entrata possono transitare senza dover avviare il ciclo Per transitare in uscita occorre premere il pulsante o usare un...

Page 2: ...Nel passaggio dal verde in una direzione al verde nell altra direzione viene dato un avvertimento di 2 secondi con verde lampeggiante e un tempo di 5 secondi con rosso in entrambe le direzioni per po...

Page 3: ...ROL UNIT POWER SUPPLY 22 LAMPS OF THE LIGHTS 22 INTERFACE WITH THE CONTROL UNIT OF THE GATE 22 PRESENCE AND CONTROL DEVICES 22 PLUG IN RECEIVER 24 OUTDOOR ANTENNA 24 ADI INTERFACE 24 CONTROL PANEL 24...

Page 4: ...accidental detachment of a conducting wire dangerous voltage parts will not come into contact with safety low voltage ones The plastic case has an IP55 insulation to connect flexible or rigid pipes us...

Page 5: ...ther vehicles once reached a predetermined threshold parking capacity Function of reservation while approaching in case of green light on the opposite direction with possibility of setting the priorit...

Page 6: ...the gate control unit to give the opening control and synchronize the switch on of the lamps with the gate motion This connection requires the terminal board G mWARNING The synchronization of the lam...

Page 7: ...ing a diode with the cathode on terminal M1 and the anode on terminal M2 for the outer side and with the cathode on terminal M4 and the anode on terminal M5 for the inner side provided that the device...

Page 8: ...up of an incoming phase CHANNEL 2 rt Starting up of an outgoing phase CHANNEL 3 rt break of the phase at rest CHANNEL 4 rt Start to the control unit of the gate without starting up of the phase mWARN...

Page 9: ...the storage of the changes made and to revert to the normal working of the control unit In order not to loose the own configuration it is compulsory exiting through this menu item mWARNING If no oper...

Page 10: ...o phases are active neither incoming nor outgoing SPEn outer lights off vErd green light on fixed roSS red light on fixed Light on at rest on the inner side Through this menu it is possible to set the...

Page 11: ...or of presence placed on the arrival side is cleared Polarity of the sensor of presence Thanks to this menu it is possible to use the control unit with sensors of presence of any kind Set the item n C...

Page 12: ...de while the phase is started up in the opposite direction If set no green is given immediately when possible otherwise the red fixed light is on Time of green The green fixed light is on during the t...

Page 13: ...e relay sending the start signal to the control unit of the gate When the control is active the terminal G3 N O is short circuited with the terminal G4 while the terminal G5 N C is open Mon a control...

Page 14: ...e the number of vehicles inside the car park is displayed for 2 seconds Cont the number of vehicles inside the car park is constantly displayed Number of vehicles inside the car park By this menu it i...

Page 15: ...ining terminals 1 to 12 OVERLOAD led will switch off 2 Remove the overload cause 3 Reinsert the terminal board extractable part and check that this led is not on again The repeating leds switch on pro...

Page 16: ...9 5 Minimum time of the red 2 0 i SCA Si no Enabling of the warning light of open gate Si C CEn Mode to send the start control on the control unit of the gate Mon Mon a control pulse is given each tim...

Page 17: ...or the power supply of the accessories C U Power Power supply from network 230V 120V W1 W2 Power supply for the lamps of the lights Z1 GREEN inner traffic light Z2 COMMON inner traffic light Z3 RED in...

Page 18: ...e of the red light has to be set in order to coincide with the opening time of the gate Once started up the phase the succession green flashing green and minimum time of red have a fixed length indepe...

Page 19: ...riving the gate In this case at rest the traffic light is green incoming and red outgoing The incoming vehicles can pass without starting up the phase To go out it is necessary to press the button or...