Installation instructions

Room air laundry dryer
One-family household

1064364-07

04/10/2022

1064364-07

3

Dimensions

The stated dimensions do not include distances from walls. To prevent disturbing noise and vibration the appliances
must not come into contact with the surrounding walls of their installation location.

595

70

15

600

500

50

58

2

6

1

4

(126

)

444

280

85

0

5

550

458

71

3

1

Cooling air inlet

2

Installation plate

3

Cooling air outlet

4

Outlet mains connection cable

Length: 1.8 m, with plug

5

Tower panel

6

Condensate drain

Drain connection: ø10.5 mm

Length of drain hose: 2.5 m

Pumping height of drain pump: ≤1200
mm

Left-hinged door

Right-hinged door

180°

1200 *

1160

1160

1200 *

180°

* Clearance space across the whole width
of the front

Summary of Contents for V4000 DualDry

Page 1: ...STA cash ier system from V ZUG Ltd Room size room climate and ventilation Keep all ventilation slits on the appliance clear and unobstructed Otherwise an adequate supply of air is not guaran teed For...

Page 2: ...on plate Open the appliance door The identification plate 1 is located bottom right 1 Installation accessories supplied The necessary installation accessories are located in the washing drum and in th...

Page 3: ...surrounding walls of their installation location 595 70 15 600 500 50 58 2 6 1 4 126 444 280 850 5 550 458 71 3 1 Cooling air inlet 2 Installation plate 3 Cooling air outlet 4 Outlet mains connection...

Page 4: ...d niche depth B based on the niche variants Use two ventilation grilles P33002 or provide a ventilation cross section 1 of min 400 cm2 to conduct the heat that is emitted from the rear of the applianc...

Page 5: ...rve the distance to the back and side walls this applies to indi vidual appliances as well as to a tumble dryer and washing machine positioned next to each other The installation plates for the tumble...

Page 6: ...pe of the manufacturer s guarantee For washing machine models 11001 11006 11010 11014 11021 11023 11025 Take out the double sided adhesive tape 1 and adhere to the mount ing surfaces 2 1 2 2 2 2 For w...

Page 7: ...parts and cables with basic insulation must not be accessible Check old installa tions Use at altitude Electrical safety is guaranteed up to 2 000 m above sea level Refer to the identification plate...

Page 8: ...n kit W56298 Use an open top fixed upright outflow pipe with the drain trap Leave a gap of 5 cm between the end of the drain hose from the tumble dryer and the level of the water in the drain trap Pos...

Page 9: ...asher dryer towers Can be connected to a concealed double drain trap Use an open top fixed upright outflow pipe with the drain trap Route drainage pipe separately or use condensate drain kit W55969 70...

Page 10: ...be selected and the appliance enters the normal operating mode The function test can be carried out regardless of the position of the air inlet and outlet flaps Carrying out the function test Insert...

Reviews: