background image

Installation instructions

Induction hob
GK46TIG | GK46TIM | GK47TIMAS

1021071-R01

28/11/2016

2

Installation accessories supplied

Oversize mounting frame:

Designation

Art. No.

Adjusting brace set

H61548

Flush installation:

Designation

Art. No.

Cementing-in instructions

J004133

Sealing tape set

H63283

Spacer set

H60330

Accessories

For all installation variants:

Designation

Art. No.

Ventilation protective plate set for niche width 550 mm

H61082

Ventilation protective plate set for niche width 600 mm

H61083

Ventilation protective plate set for niche width 825 mm

H61084

Ventilation protective plate set for niche width 900 mm

H61085

Overlying installation:

Designation

Art. No.

Stainless-steel bridge for the overlying combination of various hobs

1014361

Black bridge for the overlying combination of various hobs

1019199

Flush installation:

Designation

Art. No.

Steel angle set, installation dimension 60

H63772

Steel angle set, installation dimension 70

H63773

Steel angle set, installation dimension 80

H63774

Instant adhesive for installing the steel angle
Permabond F246 incl. activator, 50 ml tube. From Silitech AG, 3008 Bern.

B11502

Sealant set
Complete with cleaning agent, primer type 1105, cartridge with black silicone adhesive, with nozzle.
Suitable for all absorbent covering materials (wood and types of natural stone such as marble and
granite).

86.3928.85

Special primer type 107
Suitable for non-absorbent covering materials (not suitable for polyethylene, polypropylene or Teflon).

45.2771.76

Bridge set for the flush combination of various hobs (comprises two bridges)

H63789

Summary of Contents for MaxiFlex GK46TIMXSC

Page 1: ...8 GK46TIGC GK46TIGZ 31083 GK47TIMASC GK47TIMASZ 31086 GK46TIMSC O GK46TIMSZ O GK46TIMSU O 31087 GK46TIMXSC GK46TIMXSZ 31090 GK46TIMGC GK46TIMGZ 31091 GK46TIMASC GK46TIMASZ General notes The directives...

Page 2: ...bridge for the overlying combination of various hobs 1014361 Black bridge for the overlying combination of various hobs 1019199 Flush installation Designation Art No Steel angle set installation dime...

Page 3: ...efer to the identification plate for information on the required mains voltage current type and fuse protection The appliance is equipped with a connection cable which must be connected to an on site...

Page 4: ...Y Y Ri 4 9 0 1 5 0 5 0 A 680 1 600 550 1 Ra 10 B Y Y Drawer cabinet Cable length 1 7 m Cable length 1 7 m Cable length 1 7 m The clearance space must be maintained Cut out for a niche width of 550 mm...

Page 5: ...1 7 m The clearance space must be maintained 1 With symmetrical installation cut outs in the side panels are not required Type A loosely based on manufacturer B H Corner radius Ra Ri GK46TIGZ GK46TIM...

Page 6: ...A Z X X Ri GK46TIGZ GK46TIMGZ GK46TIMSZ O GK46TIMASZ GK47TIMASZ GK46TIMXSZ Cable length 1 7 m Cable length 1 7 m Cable length 1 7 m 8 5 1 0 0 0 5 1 The clearance space must be maintained 1 With symmet...

Page 7: ...rom the hob illustrated GK46TIMSU O 10 B Y Y Drawer cabinet 4 9 0 5 3 0 560 585 600 550 A H 600 5 4 5 Y Y Ri Ra Cable length 1 7 m The clearance space must be maintained Type A loosely based on manufa...

Page 8: ...w length Warning glass breakage Do not overtighten screws Reinforcing slats 25 25 mm Plate for chrome nickel steel cover The installation instructions with regard to electrical and safety related issu...

Page 9: ...wer Fan Type X Remarks GK46TIGC GK46TIMGC GK47TIMASC GK46TIMXSC GK46TIMASC GK47TIAMSC 12 mm Overlying installation GK46TIGZ GK46TIMGZ GK46TIMSZ GK46TIMXSZ GK46TIMASZ GK47TIMASZ 10 mm Flush installatio...

Reviews: