Installation instructions

Induction hob
GK46TIG | GK46TIM | GK47TIMAS

1021071-R01

28/11/2016

1

The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in
the order specified.

Validity

These installation instructions are valid for the following models:

Product family

With normal mounting frame

With dual design

With oversize frame

31078

GK46TIGC

GK46TIGZ

-

31083

GK47TIMASC

GK47TIMASZ

-

31086

GK46TIMSC/O

GK46TIMSZ/O

GK46TIMSU/O

31087

GK46TIMXSC

GK46TIMXSZ

-

31090

GK46TIMGC

GK46TIMGZ

-

31091

GK46TIMASC

GK46TIMASZ

-

General notes

The directives and standards for low-voltage installations and fire protection must be complied with when installing
in flammable material.

Identification plate

The identification plate is located next to the connec-
tion plate.

Connection plate

Identification plate

Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appli-
ance.

Summary of Contents for MaxiFlex GK46TIMXSC

Page 1: ...8 GK46TIGC GK46TIGZ 31083 GK47TIMASC GK47TIMASZ 31086 GK46TIMSC O GK46TIMSZ O GK46TIMSU O 31087 GK46TIMXSC GK46TIMXSZ 31090 GK46TIMGC GK46TIMGZ 31091 GK46TIMASC GK46TIMASZ General notes The directives...

Page 2: ...bridge for the overlying combination of various hobs 1014361 Black bridge for the overlying combination of various hobs 1019199 Flush installation Designation Art No Steel angle set installation dime...

Page 3: ...efer to the identification plate for information on the required mains voltage current type and fuse protection The appliance is equipped with a connection cable which must be connected to an on site...

Page 4: ...Y Y Ri 4 9 0 1 5 0 5 0 A 680 1 600 550 1 Ra 10 B Y Y Drawer cabinet Cable length 1 7 m Cable length 1 7 m Cable length 1 7 m The clearance space must be maintained Cut out for a niche width of 550 mm...

Page 5: ...1 7 m The clearance space must be maintained 1 With symmetrical installation cut outs in the side panels are not required Type A loosely based on manufacturer B H Corner radius Ra Ri GK46TIGZ GK46TIM...

Page 6: ...A Z X X Ri GK46TIGZ GK46TIMGZ GK46TIMSZ O GK46TIMASZ GK47TIMASZ GK46TIMXSZ Cable length 1 7 m Cable length 1 7 m Cable length 1 7 m 8 5 1 0 0 0 5 1 The clearance space must be maintained 1 With symmet...

Page 7: ...rom the hob illustrated GK46TIMSU O 10 B Y Y Drawer cabinet 4 9 0 5 3 0 560 585 600 550 A H 600 5 4 5 Y Y Ri Ra Cable length 1 7 m The clearance space must be maintained Type A loosely based on manufa...

Page 8: ...w length Warning glass breakage Do not overtighten screws Reinforcing slats 25 25 mm Plate for chrome nickel steel cover The installation instructions with regard to electrical and safety related issu...

Page 9: ...wer Fan Type X Remarks GK46TIGC GK46TIMGC GK47TIMASC GK46TIMXSC GK46TIMASC GK47TIAMSC 12 mm Overlying installation GK46TIGZ GK46TIMGZ GK46TIMSZ GK46TIMXSZ GK46TIMASZ GK47TIMASZ 10 mm Flush installatio...

Reviews: