background image

Installation instructions

Built-in variants of gas hob
Dials GAS311/321/731

1009430-10

26/07/2023

1009430-10

6

Minimum distances and installation conditions

The distance from the appliance cut-out to the back wall must be ≥50 mm and to the side walls ≥200 mm. Parts such
as side walls and reinforcing strips which protrude into the installation space under the cooking zone must be made
of fire-resistant material.
The distance between the underside of the appliance tray and any part of the cabinet beneath that is made of com-
bustible material must be ≥20 mm.

≥750

≥450

When a range hood is installed above the gas hob, the minimum distance given for
the particular range hood must be observed.
Furthermore, the minimum distances illustrated must be strictly complied with if a
lower value is stated for the range hood.

The worktop must be flat in order that it is sufficiently sealed against the ingress of
liquids.

In order to guarantee good ventilation, a space of at least 20 mm in height is ne-
cessary beneath the appliance.

If the hobs are used at an altitude of over 2,000 metres, a reduced performance
must be expected.

Gas connection

The gas connection and the conversion to another gas type must be carried out by an authorized installer.

51

46

51

46

22.4

G½ ISO 228/1

46

51

GAS311

GAS321

GAS731

65

The gas connection must be positioned so that the stop-cock and the supply connection point are accessible with the appliance in-
stalled.

The gas connection must be positioned so that it does not get detrimentally hot during operation. In particular, the gas hose assem-
blies and the appliance’s connection fittings must be clear of hot exhaust gases (e.g. from an oven).

It must be ensured that the gas hose and the mains connection do not touch any hot parts of the appliance, otherwise the gas hose
and the mains cable could become damaged through heat.

A flexible connection lead (max. length 1.5 m) must be positioned so that it runs freely and does not come into contact with any mov-
able parts of the kitchen cabinets (e.g. a drawer).

No external pressure reducer is required if the connection pressure corresponds to the details on the identification plate.

Gas type

Test gas

Connection pressure

Remark

China natural gas

12T

20 mbar

No external pressure reducer is required.

China liquid gas

20Y

28 mbar

½-inch metric thread

The gas connection on the appliance has a ½-inch external thread in accordance with ISO 228/1. If the gas installation on site already
has a corresponding counterpart, the gas appliance can be directly connected to it.

It is imperative to use the sealing ring for the front-end seal!

Summary of Contents for GAS311EKBZ

Page 1: ...nto a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use...

Page 2: ...nted combination of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 30 H63770 Steel angle set hob size 70 H63773 Designation Art no Instant adhesive for install...

Page 3: ...the top of the work surface to the underside of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces...

Page 4: ...lacement H Dimension from the top of the work surface to the underside of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the...

Page 5: ...lation must not be accessible Check old installa tions Refer to the identification plate for information on the required mains voltage current type and fuse protection The connection cable has either...

Page 6: ...be carried out by an authorized installer 51 46 51 46 22 4 G ISO 228 1 46 51 GAS311 GAS321 GAS731 65 The gas connection must be positioned so that the stop cock and the supply connection point are acc...

Page 7: ...nged All the nozzles are numbered to avoid any mix up Always disconnect the appliance from the electricity and gas mains before changing the nozzles Changing the injector nozzles Remove the pan suppor...

Page 8: ...ion for each burner Nozzle table Change injector nozzles using a 7 inch socket wrench or corresponding wrench Key Designation A Injector in hundredths of a mm B Bypass in hundredths of a mm letter cod...

Reviews: