background image

Installation instructions

Built-in variants of gas hob
Dials GAS311/321/731

1009430-10

26/07/2023

1009430-10

4

Flush installation

The layout of the hob to be fitted may differ from the hob illustrated!

H

Y – Y

B

S*

 ≥85

T

 ≥90

Drawer/
cabinet

Side panel

Ra

8.5

 0

-1

8.5

 0

-0.5

Steel angle bonded

or screw mounted

Detail Z

R0–5

6.5

+1

  0

6.5

+1

  0

C

501

501

281

Ri

H

Y

Y

Y

Y

GAS311EKBZ/GKBZ

GAS731EKBZ/GKBZ

281

Ri

≥41.5

≥41.

5

507±1

GAS321EKBZ/GKBZ

≥41.5

≥41.

5

50

7±1

60

0

287±1

275

691

Ri

Z

H

60

0

287±1

275

501

H

50

1

≥41.5

  ≥

41.

5

600

Z

697±1

Y

Y

D

60

0

Z

* The required clearance must be observed!

Type

B

H

Corner radius Ra/Ri

C/D

GAS311EKBZ/GKBZ,
GAS321EKBZ/GKBZ

≥175 mm

88 mm

5/2 mm

270/490 mm

GAS731EKBZ/GKBZ

680/490 mm

B

Required clearance for service replacement

H

Dimension from the top of the work surface to the underside of the gas connection

Ri

Corner radii of appliance for base plate

Ra

Outer corner radii of cut-out

S

Minimum distance between the top of the work surfaces and any drawer

T

Minimum distance between the cut-out in the back and any drawer

Installation

Create an accurate installation cut-out.

The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Ac-
cessories).

Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the appliance
base can be removed from below.

Prepare the cut-out and appliance according to the specifications in the enclosed cementing-in instructions and align the appliance
in the cut-out.

Fit the four adjusting braces along the circumference of the appliance to the bore holes provided and tension the appliance against
the worktop.

Summary of Contents for GAS311EKBZ

Page 1: ...nto a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use...

Page 2: ...nted combination of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 30 H63770 Steel angle set hob size 70 H63773 Designation Art no Instant adhesive for install...

Page 3: ...the top of the work surface to the underside of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces...

Page 4: ...lacement H Dimension from the top of the work surface to the underside of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the...

Page 5: ...lation must not be accessible Check old installa tions Refer to the identification plate for information on the required mains voltage current type and fuse protection The connection cable has either...

Page 6: ...be carried out by an authorized installer 51 46 51 46 22 4 G ISO 228 1 46 51 GAS311 GAS321 GAS731 65 The gas connection must be positioned so that the stop cock and the supply connection point are acc...

Page 7: ...nged All the nozzles are numbered to avoid any mix up Always disconnect the appliance from the electricity and gas mains before changing the nozzles Changing the injector nozzles Remove the pan suppor...

Page 8: ...ion for each burner Nozzle table Change injector nozzles using a 7 inch socket wrench or corresponding wrench Key Designation A Injector in hundredths of a mm B Bypass in hundredths of a mm letter cod...