V-ZUG DSMS Operating Instructions Manual Download Page 18

Addresses of the importers

Addresses of the importers

AU/NZ

V-ZUG Australia Pty. Ltd.

2/796 High Street

Kew East, Victoria 3102,

AUSTRALIA

LB

Kitchen Avenue SAL

Mirna El Chalouhi Highway

Wakim Bldg, Jdeiheh

Beirut

LEBANON

CN

V-ZUG (Shanghai) 

Domestic Appliance Co. Ltd.

Raffles City Changning Office

Tower 3

No. 1139 Changning Road

200051 Shanghai

CHINA

RU

OOO Hometek

Dubininskaya Street 57 building 1 

113054 Moscow

RUSSIA

AT/BE/
DK/DE/
ES/FR/
NO/NL/
LU/SE

V-ZUG Europe BV

Evolis 102

8530 Harelbeke

BELGIUM

SG

V-ZUG Singapore Pte. Ltd.

6 Scotts Road

Scotts Square #03-11/12/13

228209 Singapore

SINGAPORE

GB/IE

V-ZUG UK Ltd.

One Pancras Square

Gridiron Building

N1C 4G London
GREAT BRITAIN

TH

V-ZUG (Thailand) Ltd.

140/36, 17th Floor ITF Tower,

Silom Road

Suriyawong Sub-district

Bangrak District

Bangkok 10500

THAILAND

HK/MO

V-ZUG Hong Kong Co. Ltd.

12/F, 8 Russell Street

Causeway Bay

HONG KONG

TR

GÜRELLER

Anchor Sit.3A/1-2 Çayyolu

06690 ÇANKAYA/ANKARA

TURKEY

IT

Frigo 2000 S.p.A

Viale Fulvio Testi 125

20092 Cinisello Balsamo (Mil-

ano)

ITALY

UA

Private enterprise “Stirion” (MIRS

corp.)

Osipova Street 37

65012 Odessa

UKRAINE

IL

Digital Kitchen

Hataarucha 3

6350903 Tel Aviv

ISRAEL

VN

V-ZUG VIETNAM COMPANY LTD.

21st Floor, Saigon Centre, 67 Le

Loi

Ben Nghe Ward, District 1
Ho Chi Minh City, 700000

VIETNAM

18

Summary of Contents for DSMS

Page 1: ...Operating Instructions DSMS Range hood...

Page 2: ...ase follow the safety precautions Modifications Text diagrams and data correspond to the technical standard of the appliance at the time these operating instructions went to press The right to make te...

Page 3: ...first time 10 3 2 Optimizing the suction performance 10 3 3 Switching the appliance on 10 3 4 Setting the power level 11 3 5 Intensive level 11 3 6 After running time 12 3 7 Switching the appliance of...

Page 4: ...iance and have understood the haz ards involved Children shall not play with the appliance Cleaning and user mainten ance shall not be undertaken by children without supervi sion If an appliance is no...

Page 5: ...cleaning instructions may cause a fire hazard Do not flamb food under neath the range hood The appliance and surround ing components get hot dur ing operation Allow the fan flap gas deflector and oth...

Page 6: ...tioning prop erly disconnect it from the power sup ply immediately Ensure there is adequate ventilation when the extractor fan is on so as to avoid creating underpressure in the kit chen and to achiev...

Page 7: ...styrene can be dangerous for chil dren and animals Danger of suffoca tion Keep packaging material away from children and animals When carrying out maintenance work on the appliance including replacing...

Page 8: ...the cooking fumes and smells above the cooking area are passed through a recirculation box with integrated activated char coal filter the odours are largely removed from the air and it is then circula...

Page 9: ...3 Increase power level b Intensive level Switch appliance on off C Changing to extraction recirculation mode After running time 8 Saturation indicator reset After running time is switched on Saturati...

Page 10: ...uration indicator for the activated charcoal filters Switch the appliance off Depress the button for 2 seconds C flashes once in the display The appliance is now configured for the extraction mode and...

Page 11: ...switches the appliance on at power level 1 Use the or button to select the required power level The power level set is shown in the display field After opening the fan flap we recommend switching the...

Page 12: ...nce switches off 3 8 Saturation indicator Metal grease filter The symbol in the display flashes after 50 operating hours The saturation level has been reached and the metal grease filters must be clea...

Page 13: ...de years of service Do not damage the collection tray or metal grease filters when inserting removing them Removing Press the button to switch the ap pliance off Open the fan flap pull it up and there...

Page 14: ...pwards 2 3 1 Resetting the saturation indicator for the metal grease filters With the appliance switched off hold the button depressed for 3 seconds to reset the saturation indicator 8 flashes thrice...

Page 15: ...c component is defective Contact Customer Services the appliance is not extracting enough air Possible cause Solution Metal grease filters are dirty Clean metal grease filters Recirculation mode only...

Page 16: ...Dynamic Efficiency FDEhood 31 6 Fluid Dynamic Efficiency Class FDEC A Lighting Efficiency LEhood lux W 0 0 Lighting Efficiency Class LEC Grease Filtering Efficiency GFEhood 75 1 Grease Filtering Effic...

Page 17: ...2 Safety Render the appliance unusable to prevent accidents caused by improper use e g through children playing Disconnect the appliance from the mains With a fixed appliance this is to be carried ou...

Page 18: ...otts Square 03 11 12 13 228209 Singapore SINGAPORE GB IE V ZUG UK Ltd One Pancras Square Gridiron Building N1C 4G London GREAT BRITAIN TH V ZUG Thailand Ltd 140 36 17th Floor ITF Tower Silom Road Suri...

Page 19: ...O Operating elements 9 24 Operation 10 P Power level Setting 11 Product fiche 17 R Recirculation mode 8 S Safety precautions Before using for the first time 5 Correct use 6 Instructions for use 5 Not...

Page 20: ...20 9 Notes...

Page 21: ...21...

Page 22: ...22...

Page 23: ...he appliance during the guarantee period You will require the serial number SN and appliance designation to register your appliance You will find them on the identification plate of your appliance My...

Page 24: ...l Switch appliance on off C Changing to extraction recirculation mode After running time 8 Saturation indicator reset After running time is switched on Saturation indicator for the metal grease filter...

Reviews: