background image

6.

Connect flat-pin plug for operation and small 2-pin
plug for lights. 2 plug connector pairs must be
connected in total.
WARNING! Do not remove dummy connector BS
of third cable as function relevant.

BS

E

 

BS

BS

7.

Stow away cable in hood body and mount plug cover
E with 4 screws S2 (ø 3.5 x 6 mm).

8.

Close glass cover, upright hood and determine hood
height G.
WARNING: Protect the glass cover!

I

F

Q

G

H

S2

9.

Fix structure F with 12-16 screws S2 (ø 3.5 × 6 mm).
Pay attention to hood height G and alignment of struc-
ture F, the cut-outs must be laterally aligned. If blow-
out opening should be at front and back, the structure
must be turned accordingly. If possible, install bracing
ring Q in structure F.

10.

Lay flue casing H over structure F. Ensure correct
positioning of outlet opening.
For recirculation mode:
Adjust air outlet grille of upper casing to face upwards.
Air outlet grille must be in front of blow-out opening.
For extraction mode:
Adjust air outlet grille of upper casing to face down-
wards.

11.

Fix exhaust air hose to exhaust air connector. If non-
return valve flap is used, test after installation to see if
functioning properly; use metal ring if needed.

 

12.

Only for recirculation mode:
Connect diverter piece l to exhaust air hose and lay in
the structure.

 

 

Installation instructions

 

J63004.113-0

Range hood DIPQG10/DIPQG12

 

02.09.14

Island hood

 

 

Operating mode: Extraction/recirculation

 

 

5

Reviews: