background image

Range hood

DF-SLG5 / DF-SLG6 
DF-SLG8 / DF-SLG9

Operating instructions

V-ZUG Ltd

 

Summary of Contents for DF-SLG6

Page 1: ...Range hood DF SLG5 DF SLG6 DF SLG8 DF SLG9 Operating instructions V ZUG Ltd ...

Page 2: ... technical modifications for the purpose of the further development of the appliance is reserved Symbols used A Indicates step by step instructions Describes how the appliance reacts to the steps taken 䡲 Indicates a list Validity The model number corresponds to the first 3 digits on the identification plate These operating instructions apply to the models Variations depending on the model are note...

Page 3: ...ing and display elements 11 Use 12 Care and maintenance 17 Cleaning the housing 17 Cleaning the grease filter 18 Replacing the standard activated charcoal filter 20 Cleaning and replacing the long life activated charcoal filter 21 Replacing halogen spotlights 22 Trouble shooting 23 What to do if 23 Accessories and spare parts 24 Technical data 25 Disposal 26 Notes 27 Index 29 Repair service 31 Qui...

Page 4: ...ty Before using for the first time 䡲 The appliance must be installed and connected up to the electricity supply according to the separate installation instructions The necessary work should be carried out by a qualified fitter or electrician 䡲 Dispose of the packaging material in accordance with local regulations The appliance corresponds to recognised technology standards and the relevant safety ...

Page 5: ...necessary 䡲 Use original spare parts only 䡲 Retain these operating instructions for future reference If you sell or pass the appliance on to a third party please ensure these operating instruc tions together with the installation instructions accompany the appliance In this way the new owner can inform themselves about how to use the appliance correctly and read the pertinent safety precautions Ch...

Page 6: ...re Constantly monitor the temperature of the cooking oil keeping it below the temperature at which it can catch fire Change the cooking oil regularly dirty oil catches fire more easily than clean oil 䡲 Clean the filters regularly Failure to do so can increase the fire hazard due to the build up of grease in the grease filter 䡲 Do not operate the individual cooking zones of the cooking surface with...

Page 7: ...n adequate flow of fresh air must be guaranteed e g via non closable openings in doors or windows and in combination with an air intake exhaust air wall box or by other technical means 䡲 When carrying out maintenance work on the appliance including replacing the light bulb cut off the electricity supply to the appliance remove the screw fuse from the holder or switch the circuit breaker off or dis...

Page 8: ...ver the stove top are removed by an activated charcoal filter The cleaned air then flows through the grating above on the appliance back into the room Using an air recycling cartridge LRC1 The appliance suctions the fumes over the stove top through the grease filter which retains the grease particles The air is then blown through a pipeline to the air recycling cartridge An activated charcoal filt...

Page 9: ... filter not included in delivery The extractor fan has 4 power levels 1 2 3 P 䡲 1 low 2 medium 3 high power P intensive level 䡲 The levels 1 to 3 are suitable for continuous operation 䡲 The level P power is used for brief intensive extraction of fumes e g when searing Level P is available for 5 minutes After this time operation automatically continues at level 2 ...

Page 10: ... Appliance description 10 Construction 1 Glass shield extractable 2 Operating elements 3 Metal grease filter 4 Grip flap 5 Halogen spotlight 6 Halogen spotlight holder 1 4 5 6 2 3 ...

Page 11: ...f metal grease filter and activated charcoal filter Illumination ON OFF Ventilation OFF resetting of saturation indicator Automatic running on Decrease power level Increase power level Depending on the model and features the specification of the appli ance may differ from the standard specification described herein 1 ...

Page 12: ...witched off with the button A To switch off the fan press the button Once the appliance is connected to the mains electricity the readi ness indicator lights up The appliance operates most effectively when the glass shield is completely pulled out Level P is available for 5 minutes After this time operation automati cally continues at level 2 To select power level P again repeatedly press the butt...

Page 13: ...er level 䡲 Power level 1 20 minutes 䡲 Power level 2 15 minutes 䡲 Power level 3 10 minutes 䡲 Power level P 5 minutes After the specified time the fans automatically switch off A To switch off the automatic running on function press the button again The readiness indicator stops flashing Operation continues at the set power level Switching the illumination on off A To switch on press the button A To...

Page 14: ...cleaned Resetting the saturation indicator A Depress the button for 3 seconds The indicator light goes out Activating deactivating the saturation indicator of the standard activated charcoal filter A To activate hold the buttons and pressed until lights up in the digital display A To deactivate hold the buttons and pressed until goes out in the digital display The saturation is not displayed in st...

Page 15: ... up after 160 hours of operation The saturation level has been reached The current extraction level flashes alternatingly with in the digital display A The standard activated charcoal filter must be replaced Resetting the saturation indicator A Depress the button for 3 seconds The indicator light goes out The saturation is not displayed in stand by mode ...

Page 16: ...tings power level and light used during the last period of operation remain saved These are reactivated once the glass shield is reopened An exception is the power level P A Pull out the glass shield 1 partially or completely In this position the stove top lighting and the various power levels can be switched on and off at will The last used settings power level and light are reactivated An except...

Page 17: ...rease and condensate water can build up around the grease filter on the inside A Clean using a slightly damp cloth and detergent if necessary and wipe dry Take care that no water gets into the housing If water gets into the housing it can cause damage Do not use abrasive cleaners scouring pads steel wool etc to clean the appliance as they can damage the surface ...

Page 18: ...the service life of the grease filter is unlimited A Clean the grease filter in the dishwasher A Select the dishwasher program Intensive or Heavy with warm pre rinsing If a dishwasher is not available A Clean the grease filter in a rinsing bath A Soak the filter approx 2 hours in a hot rinsing bath and then clean with a scouring brush Grease filters can become discoloured due to cleaning This in n...

Page 19: ...ottom Installing the grease filter A Pull out the glass shield completely A Grasp the grease filter and make sure that the grip flap is facing down Insert fixed centring pins at the back in the retaining slots in the housing A Ensure that all centring pins are seated in the correct retaining slots Only then will the grip flap latch completely in place The grease filter is correctly inserted if it ...

Page 20: ...er A Push the two red retaining slides 2 on the standard activated charcoal filter 1 upward while lifting the filter from below as you pull it out of the holder 3 A Slide the new standard activated charcoal filter upward under the bracket and fix it below on the holder 3 Allow the red retaining slides 2 to latch in place A Reinsert the metal grease filter A Screw the fuse back in or switch the cir...

Page 21: ...ble the filter can also be soaked for an hour at 60 C in a sink with a standard detergent Afterward rinse well To reactivate the activated charcoal the long life filter must be dried without its frame in an oven A Select top or bottom heating element or 100 C hot air and allow the filter to dry 60 minutes on the wire shelf A Remove and clean the metal grease filter A Take out the long life activat...

Page 22: ...g from the halogen spotlight A Replace the defective halogen spotlight with another of the same type max 20 Watt A Re attach the fitting to the halogen spotlight A Connect the 2 pin plug to the halogen spotlight A Insert the complete halogen spotlight into the appliance A Insert the grease filter and slide in the glass shield A Screw the screw locking device back on and switch on the circuit break...

Page 23: ... the fuse A Reset the circuit breaker 䡲 Interruption in the power supply A Check the power supply 䡲 The halogen spot is defective A Replace the halogen spot Possible cause Solution 䡲 The metal grease filter is dirty A Clean the metal grease filter 䡲 The activated charcoal filter for recirculation models is spent A Replace the standard activated charcoal filter A Clean the long life activated charc...

Page 24: ...ve model number and exact description when ordering parts Halogen spotlight 12 V 20 W Metal grease filter Standard activated charcoal filter Long life activated charcoal filter The halogen spotlight is also available from specialist retailers ...

Page 25: ...25 Technical data Electrical connection A See identification plate A Remove the grease filter The identification plate is located on the inside of the appliance ...

Page 26: ...socket or have the appliance disconnected from the mains by a qualified electrician Then cut off the mains cable Disposal 䡲 The old appliance should not be discarded as worthless rubbish If disposed of correctly the raw materials can be recovered for recycling 䡲 The symbol on the identification plate warns that the appliance may not be disposed of in normal household waste 䡲 The appliance must be ...

Page 27: ...27 Notes ...

Page 28: ... Notes 28 ...

Page 29: ...nnection 25 Equipment 9 Extraction model 8 Extractor fan 12 F Faults 23 G Glass shield 16 Grease filter Cleaning 18 Installation 19 Removal 19 Saturation indicator 14 H Halogen spotlights Replacing 22 I Identification plate 25 Illumination 13 L Long life activated charcoal filter 21 M Maintenance 17 Malfunction 31 Metal grease filter Saturation indicator 14 Model no 2 O Operating elements 11 Order...

Page 30: ...turation indicator for standard activated charcoal filter Activating 14 Deactivating 14 Selecting the power level 12 Service agreement 31 Service centre 31 Spare parts 24 Ordering 31 Standard activated charcoal filter Replacing 20 Saturation indicator 15 Switching off 16 Switching on 12 Symbols 2 T Technical data 25 Type 2 U Use 12 Using for the first time 4 V Validity 2 ...

Page 31: ... If the appliance is not working properly contact your nearest V ZUG Ltd service centre using freephone 0800 850 850 and stand in close proximity to the appliance Queries orders service agreement For administrative and technical queries or problems as well as for ordering spare parts and accessories please contact our head office in Zug on telephone number 41 0 41 767 67 67 As regards the maintena...

Page 32: ...A Pull out the glass shield Extractor fan A Press the button Illumination A Press the button Switching off A Press the button or A push in the glass shield J377 13 5 V ZUG Ltd Industriestrasse 66 6301 Zug Tel 41 0 41 767 67 67 Fax 41 0 41 767 61 61 vzug vzug ch www vzug ch Service Centre Tel 0800 850 850 ...

Reviews: