If the appliance is installed in a very humid environment,
condensation can build up on the outside of the unit.
Always make sure the installation location is well venti‐
lated .
-
The more coolant there is in the appliance, the larger
the room in which the appliance is installed must be. If
the room is too small, any leak may create a flammable
mixture of gas and air. For each 8 g of coolant the instal‐
lation space must be at least 1 m
3
. Information on the
coolant is on the model plate inside the appliance.
2.1.1 Supporting floor
-
The floor of the installation site must be horizontal and
even.
-
If the floor is not entirely even, the kitchen cabinet
housing the appliance must be levelled with support
blocks.
2.1.2 Positioning
-
Do not install the appliance in direct sunlight, next to an
oven, radiator or similar.
-
Only fit the appliance into solid kitchen units.
Note
Please contact Customer Services to acquire a kit to limit
the door opening angle to 90° for appliances with soft close
mechanisms.
2.2 Installing multiple appliances
NOTICE
Risk of damage due to condensate!
u
Do not install the appliance directly alongside a further
refrigerator/freezer.
NOTICE
Risk of damage due to condensation!
u
Do not install the appliance directly above another refrig‐
erator or freezer.
These appliances are designed for a variety of installation
options. Combine appliances only if the appliance is suit‐
able. The following table shows the installation options by
model:
Installation
option
Model
Single
All models
Side-by-side
(SBS)
Model names starting with S....
Stacked
Models with a maximum recess height of
880 mm and with a heated cover can be
“stacked”.
Top appliance: up to a maximum recess
height of 140 mm
Fig. 1
Build each appliance into a separate recess.
2.3 Mains connection
WARNING
Improper use!
Fire. If a mains cable/plug comes into contact with the back
of the appliance, the mains cable/plug can be damaged by
appliance vibrations and this may result in a short circuit.
u
Stand the appliance so that it is not touched by connec‐
tors or main cables.
u
Do not connect any appliances to sockets in the area of
the back of the appliance.
u
Multi-sockets/power distributors and other electronic
appliances (such as halogen transformers) may not be
placed and operated at the back of appliances.
3 Appliance dimensions
Fig. 2
A (mm)
B (mm)
C (mm)
Cooler V200
88G
559
546
872
Cooler V600
122KG
1213
Freezer V4000
178N
Cooler V4000
178K
Cooler V4000
178 KG
1770
Appliance dimensions
50
* Depending on model and options