8 Care and maintenance
Inserting the filter cassette
▸ Reassemble in the reverse order.
▸ Make sure the filter cassette is fully inserted.
Resetting the saturation indicator alarm for the grease filters
▸ In the display, touch the grease filter .
–
The «Filter» menu is displayed.
▸ Reset the filter as described.
Filter
Reset grease filter
Alternatively, the saturation indicator alarm can also be accessed via the «Filter»
menu of the range hood.
Cleaning the activated charcoal filter
The activated charcoal filter should be cleaned and reactivated every 3 to 6 months with
normal use or whenever the saturation indicator alarm is triggered. Depending on intens-
ity of use, do not exceed 5–8 regeneration cycles. If properly cared for, the service life of
the activated charcoal filter is up to 3 years. The spent activated charcoal filter can be
disposed of in the household waste or at a suitable recycling point.
Switch the appliance off. The range hood must be switched off so that no functions
such as after-running time, CleanAir or room ventilation mode are active. The fan
must not be active.
Removing,cleaning and regenerating
▸ Remove the filter cassette
1
.
▸ Remove the activated charcoal filter
2
from the
appliance by the handle.
▸ Heat the activated charcoal filter
2
in the oven
3
.
▸ Select top/bottom heat or hot air at 200 °C and
regenerate on the wire shelf for 60 minutes.
▸ Allow to cool down.
▸ Reassemble in the reverse order.
200°C
1h
2
1
3
33