background image

11 

Service & Support

The «Trouble-shooting» section gives you valuable tips on how to deal with minor
malfunctions yourself, saving you the time and trouble of calling out a service tech-
nician and any cost that goes along with it.

Information on the V-ZUG warranty can be found at 

www.vzug.com

 →Service

→Warranty information. Please read this information carefully.
Please register your V-ZUG appliance straightaway:

online at 

www.vzug.com

 →Service →Online warranty registration or

using the enclosed registration card.

This will allow you to take advantage of the best possible support in the event of a fault
in the appliance during the guarantee period. You will require the serial number (SN) and
appliance designation to register your appliance. You will find them on the identification
plate of your appliance.
My appliance information:

SN:

 __________________________

Appliance

: _______________________________

Please have this appliance information to hand when contacting V-ZUG. Thank you.

▸ Remove the metal grease filters.

The identification plate is located on the inside of the appliance.

A second identification plate is included in the scope of delivery and should be re-
tained for the purpose of appliance identification.

Your repair order

Call the free service number 0800 850 850 to contact your nearest
V-ZUG service centre. You can arrange an on-site visit by us by phone if you wish.

General queries, accessories and service agreement

V-ZUG will be happy to help you with any general administrative or technical queries, to
accept your orders for accessories and spare parts and to inform you about our pro-
gressive service agreements. You can contact us by calling tel. +41 58 767 67 67 or by
going to our website at www.vzug.com.

23

Summary of Contents for AiroClearCabinet V400

Page 1: ...Operating instructions DFSE 5 6 AiroClearCabinet V400 Range hood...

Page 2: ...he time these operating instructions went to press The right to make technical modifications for the purpose of the further development of the appliances is reserved Validity The model number correspo...

Page 3: ...Switching the appliance on 9 3 3 Extractor fan 9 3 4 Intensive level 10 3 5 After running time 10 3 6 Illumination 10 3 7 Switching the appliance off 10 3 8 Saturation indicator 11 4 Care and mainten...

Page 4: ...or lack of experi ence and or knowledge provided they are supervised or have been instructed on the safe use of the appliance and have understood the haz ards involved Children shall not play with the...

Page 5: ...it chen and to achieve optimal air extrac tion Avoid a cross current of air which could blow the cooking vapours over the cooking area If other appliances fired by gas or other fuels are being used at...

Page 6: ...e electricity supply to the appliance remove the screw fuse from the holder or switch the circuit breaker off or disconnect from the mains supply How to avoid damaging the appliance Observe the cleani...

Page 7: ...eing filtered through the metal grease filters the cooking fumes and smells above the cooking area are passed through an activated charcoal filter The filtered air is then circulated back into the roo...

Page 8: ...tching the extractor fan off reducing the power level Switching the extractor fan on increasing the power level Power level display Intensive level display Switch illumination on off Reset after runni...

Page 9: ...uration indicator for the activated charcoal filter Switch the appliance off Hold the and buttons depressed for 3 seconds Power level 1 flashes in the display The appliance is now configured for the e...

Page 10: ...ted the display flashes according to the table below and then switches off automatically Level After running time 1 20 minutes 2 15 minutes 3 10 minutes Intensive 5 minutes 3 6 Illumination Press the...

Page 11: ...ate this function if the appliance is being used in the recirculation mode 4 Care and maintenance 4 1 Cleaning the housing Take care that no water gets into the housing of the appliance If water gets...

Page 12: ...fixture Clean the grease filter 3 2 3 1 Cleaning Clean the grease filters 3 in the dishwasher Select an intensive or heavy wash programme with a warm prewash Cleaning may cause the metal grease filter...

Page 13: ...mal use or whenever the saturation indicator flashes If properly cared for the service life of the long life activated charcoal filter is 3 years Disconnect the appliance from the mains and unscrew t...

Page 14: ...an be disposed of in the household waste or at a suitable recycling point Installing Insert the activated charcoal filter mat 3 into the frame 4 Insert the activated charcoal filter unit 2 into the br...

Page 15: ...it breaker Removing Installing Pull the deflector plate completely out and remove both grease filters Push bar 1 and move the activated charcoal filter unit 2 down and out of the bracket Replace and d...

Page 16: ...n the power supply Check the power supply LED light bulb is defective Contact Customer Services the appliance is not extracting enough air Possible cause Solution The metal grease filters are dirty Cl...

Page 17: ...gnation of the accessory or spare part when ordering parts Metal grease filters Long life activated charcoal filter Standard activated charcoal filter 7 Technical data Electrical connection See identi...

Page 18: ...D Air flow at minimum speed Qmin m3 h 240 0 205 0 Air flow at maximum speed intensive or boost excluded Qmax m3 h 515 0 310 0 Air flow at intensive or boost setting Qboost m3 h 625 0 410 0 Airborne a...

Page 19: ...dents caused by improper use e g through children playing Disconnect the appliance from the mains With a fixed appliance this is to be carried out by a qualified electrician Then cut the mains cable o...

Page 20: ...itial set up 5 Intensive level 10 M Model designation 2 Model number 2 N Notes 21 O Operating elements 8 24 Operating the appliance 9 P Product fiche 19 Q Queries 23 R Recirculation mode 7 S Safety pr...

Page 21: ...21 10 Notes...

Page 22: ...22...

Page 23: ...identification plate of your appliance My appliance information SN __________________________ Appliance _______________________________ Please have this appliance information to hand when contacting...

Page 24: ...n on increasing the power level Power level display Intensive level display Switch illumination on off Reset after running time saturation indicator V ZUG Ltd Industriestrasse 66 CH 6302 Zug Tel 41 58...

Reviews: