… Technical data
47
Noise measurement
The measurement is to be carried out in accordance with the European Norm
EN 60704-2-3, section 6.1.3.
A
The appliance is to be installed in accordance with the accompanying installation-
instructions. In particular, for certain models it is important to secure the slide plate
to the floor.
A
Feed the inlet and drain hose, as shown in the installation instructions, into the ad-
jacent niche.
A
A 19 mm thick chipboard (density: > 750 kg/m³) is to be fitted as a decorative
plate on the door of the appliance in accordance with the accompanying installa-
tion instructions. The decorative plate should reach down to the floor, with a gap
of 1–2 mm for ventilation.
A
To level out any unevenness between the test cabinet and the floor, seal any gaps
between the test cabinet and the floor. This will improve the reproducibility of the
measurement.
A
Before conducting a noise emission test, the appliance door must be opened wide
and then closed again.
A
As described in the norm, the measurement is to be carried out without detergent
and rinse agent. Rinse agent dosage should therefore be set to «1».
A
Fill the salt reservoir with regeneration salt and then fill up with water.
A
Set the water hardness setting in accordance with the operating instructions.
Please note the installation instructions accompanying the appliance.