43
Technical data
Dimensions
Plumbing
Electrical connection
Safety concept
Provided power is going to the appliance, the electronic control unit monitors the ap-
pliance. Any malfunction is indicated by fault and error messages.
Overflow protection
The electronic control unit monitors the water level in the appliance. In the event of a
malfunction, the drain pump turns on, stopping the supply of water to the appliance.
SMS 55
EURO 60
Height (with slide plate):
76 cm
76 cm
Height (with plinth):
–
80–88.5 cm
Width:
54.6 cm
59.6 cm
Depth:
57.1 cm
57.1 cm
Weight:
40 kg
40 kg
Cold or warm water up to 60 °C:
G¾“
Permitted pressure of water supply:
0.1–0.6 MPa (1–6 bar)
Max. pumping height:
1.2 m
Voltage:
230 V~ 50 Hz
Rated load:
2200 W
Electrical fuse:
10 A
In the event of a power failure, the overflow protection sys
tem is rendered ineffective. Hence, the water tap should be