background image

Installation instructions

Oven / CombiSteam oven
Construction type 60-600

J32A.113-0

26.11.11  WIMA

1

 

These installation instructions apply to the models:

 

Identification plate

Open the appliance door. The identification plate is located on the left trim panel 
(see illustration).

Connection plate

Open the connection box and pivot downwards.  The connection plate is located 
next to the connection terminal in the connection box (see «Installation»).

Refer to the identification plate for specifications for the required mains voltage, current type and fuses.

Application height of the appliance: up to max. 2000 m above sea level

 

The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order 
specified.

Validity

Oven:
CombiSteam oven:

32A, 34A, 36A, 38A, 40A, 42A, 45A, 48A, 51A, 54A
61A, 63A

General notes

If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be 
strictly observed.
To ensure good ventilation, the niche in which the appliance stands must have a supply air opening of at least 25 cm

2

.

This appliance is considered to be suitable for use in countries having a warm damp equable climate (WDaE). It may also be 
used in other countries. If used in warm damp equable climated countries, the appliance is to be supplied through a residual 
current device (RCD) having a rated residual operating current not exceeding 30 mA. 

Electrical connections

Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage 
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An 
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and 
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching 
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and 
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should 
always be checked.

Reviews: