•• Mode2:Door•Lock•Controlled•With•Internal•Power
Note:
1.Electronic•lock•of•power-on-to-unlock•shoule•be•
used.
2.The•door•lock•is•limited•to•12V,and•holding•current•
must•be•less•than•250mA
3.The•door•lock•control•is•not•timed•from•Exit•
Button(EB).
4.•The•Unlock•Mode•Parameter•of•Monitor•must•be•
set•to•0•(by•default).
The•lock•can•be•directly•connected•with•the•door•station•and•the•power•through•monitor.During•unlock•
operation,the•monitor•will•close•screen•automatically.
1R 2W 3Y
4B
Connect to Monitor
JP/LK Jumper position in
Unlock mode:0
2-3
1 2 3
VT596(F)
S-
S+
PL
1
R
2
W
4
B
3
Y
DC+
DC-
Black
Red
White
+
-
LOCK
AC ~
-5-
5. Functions Setting Up
This•section•explains•the•settings•of•each•function,please•refer•to•the•following•table:
About•the•setting•mode:
Input•the•master•code•to•switch•to•the•setting•mode,•and•input•the•corresponding•setting•code•to•perform•
the•settings•for•the•function•you•want.•After•settings•have•been•made,•input•the•following•setting•codes•to•
continue•the•setting•operation.•Press•"• •"•to•exit•the•setting•mode.
•• The•example•is•set• •as•cancel•button•and•#•as•confirm•button,please•refer•to•
*/#•function•setting•for•detail•information.
•• Forbid•to•slide•to•touch•the•digital•keypad,it•may•cause•mistaken•key,the•
correct•operation•is•using•your•finger•to•press••the•digital•you•desired.
•• You•should•press“confirm”button•after•finish•inputting•the•code•number•each•
time,otherwise,the•operation•will•be•canceled•automatically•in•10s.