V-Tec VT596/KP User Manual Download Page 10

Input the master code.
(Default:   [                  ]+[#] )

(red)

ON

(blue)

OFF

Beep+, Beep

(red)

ON

(blue)

ON

Beep+, Beep

(red)

ON

(blue)

ON

Beep+, Beep

(red)

ON

(blue)

ON

Beep+, Beep

(red)

ON

(blue)

OFF

Beep+

(red)

ON

(blue)

OFF

Beep+

(red)

ON

(blue)

OFF

Beep+

Inputting of code (ex.: 2011)
1~12 digits

   14.Setting the code 

        for user 

   13.Setting the code

      forTemporary2

Input the setting code. 

Input the setting code. 

   12.Setting the code 

        forTemporary1

18+#

19+#

21+#

2011+#

Inputting of code (ex.: 1006)

1~12 digits

1006+#

Inputting of code (ex.: 2011)

1~12 digits

2011+#

Input the setting code.

(ex.:21)

20~99

When the  “     cancel”  key is pressed, the LED lights off, the buzzer beeps, and the system exits the setting mode

When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode

(red)

OFF

(blue)

OFF

Beep, Beep+

 *

- When input the correct temporary password to release the door,

the system will clear the temporary password after 60 seconds 

automatically.But you should know that the password is valid within

60 seconds after inputing the correct temporary password

- If the password length exceeds 12 digits, the system will sent out

the sound of “beep,beep,beep,beep”,and the digitals you input 

before will be cleared at the same time.

- The temporary code can not be set the same as the master code 

and user code.

- The user code  is used to release 

the lock,80 group passwords can 

be supported.

- If the password length exceeds 

12 digits, the system will sent out 

the sound of “beep,beep,beep,beep”,

and the digitals you input before 

will be cleared at the same time.

- The user code can not be set the 

same as the master code and

temporary code.

10.Interference resistant 

     grade setting

(Default 2)

(blue)

ON

Beep+, Beep

(blue)

OFF

Beep+

Input the setting code. 

09+#

Inputting of code (ex.: 3)

range:0~5

3+#

Setting items

Step 1

Step 2

Step 3

Step 1

Step 2

Step 3

Step 1

Step 2

Step 3

Step 1

Step 2

Step 3

- The larger you set the interference 

resistant grade,the stronger it will be,

but the sensitivity of the keypad will 

be more lower.

- The interference resistant grade 

setting also will activatethe keypad 

checking.

-9-

Summary of Contents for VT596/KP

Page 1: ...VT596 F KP USER MANUAL EN VT596 KP VT596F KP 4 Wire Video Intercom System Read this manual carefully before using the product and keep it well for future use...

Page 2: ...dicator blue Nameplate Call Button Microphone 90 mm 28 mm 176 mm 220 mm 119 mm 1 4 5 6 9 8 0 7 2 3 1 4 5 6 9 8 0 7 2 3 Camera Lens Touch Sensitive Digital Keypad Speaker Nameplate Call Button Screws f...

Page 3: ...12V present when outdoor station calling or being monitored 2W Power negative GND 3Y Image signal Video signal 4B Talk and control signal Audio signal PL External lock power input connect to the power...

Page 4: ...o the mounting box and use screws supplied to fix the panel Place name label Connect the cable correctly and adjust right angle for camera adjust camera angle PS 4 core cable 3 Placing Name Label Pres...

Page 5: ...ic lock can be used Incidentally in this mode you can continue talking and monitoring during unlock operation Note 1 The external power supply must be used according to the lock 2 The inside relay con...

Page 6: ...Functions Setting Up This section explains the settings of each function please refer to the following table About the setting mode Input the master code to switch to the setting mode and input the co...

Page 7: ...continually lit 00s 10 seconds 02 4 Setting the unlock time 01 to 99 seconds 1 seconds 03 5 Setting the unlock mode 0 opened 1 closed opened 04 6 Operation tone settings 0 on 1 off on 05 7 Reset code...

Page 8: ...0 range 00 or 10 99 Inputting of code ex 09 range 01 99 3 Setting the key illumination time 4 Setting the unlock time 2 Setting the master code Default 1234 Default 10s Default 1s Inputting of new mas...

Page 9: ...d the system exits the setting mode When there isn t any operation in 10s the LED lights off the buzzer beeps and the system exits the setting mode The unlock mode is used to match the type of lock If...

Page 10: ...now that the password is valid within 60 seconds after inputing the correct temporary password If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and th...

Page 11: ...utton and input the user code again If 10 times incorrect access codes are continuously attempted the release function is forbidden and the input operation is disabled for 60 seconds During this time...

Page 12: ...or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional Power Supply DC 16 20V Power Consumption Standby...

Reviews: