background image

VT596(F)/KP USER MANUAL(EN)

VT596/KP 

VT596F/KP 

4 Wire Video Intercom System

Read this manual carefully before using the product, and keep it well for future use.

Summary of Contents for VT596/KP

Page 1: ...VT596 F KP USER MANUAL EN VT596 KP VT596F KP 4 Wire Video Intercom System Read this manual carefully before using the product and keep it well for future use...

Page 2: ...dicator blue Nameplate Call Button Microphone 90 mm 28 mm 176 mm 220 mm 119 mm 1 4 5 6 9 8 0 7 2 3 1 4 5 6 9 8 0 7 2 3 Camera Lens Touch Sensitive Digital Keypad Speaker Nameplate Call Button Screws f...

Page 3: ...12V present when outdoor station calling or being monitored 2W Power negative GND 3Y Image signal Video signal 4B Talk and control signal Audio signal PL External lock power input connect to the power...

Page 4: ...o the mounting box and use screws supplied to fix the panel Place name label Connect the cable correctly and adjust right angle for camera adjust camera angle PS 4 core cable 3 Placing Name Label Pres...

Page 5: ...ic lock can be used Incidentally in this mode you can continue talking and monitoring during unlock operation Note 1 The external power supply must be used according to the lock 2 The inside relay con...

Page 6: ...Functions Setting Up This section explains the settings of each function please refer to the following table About the setting mode Input the master code to switch to the setting mode and input the co...

Page 7: ...continually lit 00s 10 seconds 02 4 Setting the unlock time 01 to 99 seconds 1 seconds 03 5 Setting the unlock mode 0 opened 1 closed opened 04 6 Operation tone settings 0 on 1 off on 05 7 Reset code...

Page 8: ...0 range 00 or 10 99 Inputting of code ex 09 range 01 99 3 Setting the key illumination time 4 Setting the unlock time 2 Setting the master code Default 1234 Default 10s Default 1s Inputting of new mas...

Page 9: ...d the system exits the setting mode When there isn t any operation in 10s the LED lights off the buzzer beeps and the system exits the setting mode The unlock mode is used to match the type of lock If...

Page 10: ...now that the password is valid within 60 seconds after inputing the correct temporary password If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and th...

Page 11: ...utton and input the user code again If 10 times incorrect access codes are continuously attempted the release function is forbidden and the input operation is disabled for 60 seconds During this time...

Page 12: ...or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional Power Supply DC 16 20V Power Consumption Standby...

Reviews: