background image

-4-

PARTS AND FUNCTIONS

Mounting

1

2

3

4

5

AcDbMLeader (ACDB_MLEADER_CLASS)

AcDbMLeader (ACDB_MLEADER_CLASS)

Rain cover

Rain cover

The distance between 

the top of main unit 

and rain cover should 

be not less than 3mm.

Main unit

Main unit

≥3mm

1

2

3

4

5

AcDbMLeader (ACDB_MLEADER_CLASS)

AcDbMLeader (ACDB_MLEADER_CLASS)

AcDbMLeader (ACDB_MLEADER_CLASS)

1. Connect the cable
2. Drill holes in the wall to match the size of screw stoppers,

 

then attach the rain cover and 

main unit to the wall

. T

he distance between the top of main unit and rain cover should be not

less than 3mm
3. Install the name plate
4. Attach the front panel to the main unit

5. Use the special screwdriver and the screws to fix the panel

1. Drill a hole in the wall to match the size of mounting box,

 

then 

install

 the mounting box

2. Loosen the high screws to install the name plate 
3. Connect the cable
4. Attach the front panel to the mounting box,then use the special screwdriver and the screws to 

fix the panel

5. Finish the installation

Surface mounted

Flush mounted

The installation height is suggested to 145~160cm

* The camera angle view of surface mount model may be less than 170

0

Summary of Contents for D250

Page 1: ...correct operation Keep this manual well for future reference RF CARD RF CARD RF CARD RF CARD RF CARD RF CARD DT607A ID S4 DT607 ID FE S1 DT607 ID FE S2 DT607F ID FE S4 DT607 ID FE S3 DT607 ID FE S4 Mo...

Page 2: ...de 8 Setting Camera Resolution 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Ima...

Page 3: ...7 6 5 12 11 12 13 13 2 2 Surface mounted Flush mounted 1 Microphone 2 UNLOCK indicator 3 Call indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rain cover 1...

Page 4: ...e wall The distance between the top of main unit and rain cover should be not less than 3mm 3 Install the name plate 4 Attach the front panel to the main unit 5 Use the special screwdriver and the scr...

Page 5: ...connect the bus line and the electric lock L1 L2 Connect to the bus line no polarity PL External lock power input connect to the power positive power S Lock power output S Lock power output connect to...

Page 6: ...cator will lights up Unauthorized user fob card will make 3 beep sounds Fisheye Camera External Motion Detection Please note that this function requires the monitor with fisheye function to support Th...

Page 7: ...dicators and by the sounding of the buzzer Order Settings Setting range Default value 1 Door station address 0 3 0 2 Door station calling mode Standard Group calling mode Standard calling mode 3 Camer...

Page 8: ...K Indicator OFF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep Beep ID 0 for 1st door s...

Page 9: ...address 03 Call button D call the monitor with address 04 Call button A Call all monitors in group address from 00 15 one of the monitor should be set to 00 Call button B C D Call all monitors in grou...

Page 10: ...ndicator ON TALK Indicator OFF Buzzer Beep Press KEY_1 button to set the unlock mode to Normally opened UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press KEY_1 button again to set the unlo...

Page 11: ...lumination mode to Normally on UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press KEY_3 button again to set the nameplate illumina tion mode to Normally off UNLOCK Indicator ON TALK Indicat...

Page 12: ...to Press KEY_4 UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Press KEY_1 button to set the ri...

Page 13: ...hen answering the call image switching reminder is not effective Zoom mode When answering the call the image will be displayed on full screen for 5 sec onds then switch to Zoom image to remind to ente...

Page 14: ...Hz Authorizing master cards By default there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE but you should know that the master card can be authorized by users at any time That mea...

Page 15: ...l exit out setting mode automatically If current access is controlled by door station next access switching setting is controlled by DT ACC UNLOCK Indicator Blink two times TALK Indicator OFF Buzzer B...

Page 16: ...equence UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER CARD DELETE again to exit UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Show the master card o...

Page 17: ...Unlock Mode must be set to 0 default 1 The external power supply must be used according to the lock specs 2 The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3 The jumper must be taken o...

Page 18: ...IM BUS DS L1 L2 PL S S ID 0 Code 1 DIP6 on 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches RF CARD PC6A AC 100 240VAC 100 240VAC DBC4A1 A B C D OFF ON Impedance switch BUS IM BUS DS PC6A AC ID 0 1st door stati...

Page 19: ...n villa Refer to Page 9 Distributor is unnecessary in full audio system and IN OUT mode is recom mended For the last monitor connected to the system DIP6 should set to ON ID 0 Code 1 DIP6 off Optional...

Page 20: ...stributor for the extension WIRING DBC4A1 A B C D RLC DBC4A1 OFF ON Impedance switch BUS IM BUS DS Code 1 DIP6 on Code 2 DIP6 on Code 3 DIP6 on Code 4 DIP6 on ID 0 RF CARD PC6A AC 100 240VAC Optional...

Page 21: ...acture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional APPENDIX Power supply DC 24V Power consumption Standby 0 8W Working 3W Ca...

Page 22: ...limited in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40...

Page 23: ...23 B A C 2 2 DBC4A1 RF CARD PC6A Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Star Topology Wiring Mode With DBC4A1...

Page 24: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved...

Reviews: