background image

4.  Operation for ring selection

Select 

User Setup

 item on main menu page to enter setup page.Select 

Door Station Call 

Tone

Inercom Call Tone

 or 

DoorBell Call Tone

 item, There are 12 pieces ring tones can 

be selected.use     /   Button to select last/next ring tone, press MENU button to save and exit.

Door Station Call Tone

:set the ring tone calling from outdoor station.

Intercom Call Tone

:set the ring tone calling from other apartments.

DoorBell Call Tone

:set the ring tone calling from door bell.

Door Station Call Tone

Selected:           06

Cancel

Save&Exit

Last/Next

1 Carmen           5 Sonatine                  9 Do Re Me
2 Ding Dong     6 Edelweiss              10 Happy Birthday
3 Rain                  7 Going Home        11 Jingle Bells
4 For Alice          8 Congratulation   12 Telephone Ring

User Setup  (1)

Door Station Call Tone  ...
Intercom Call Tone  ...
DoorBell Call Tone  ...
Date&Time Setup  ...
Next Page

Exit

OK

Select Item

5.  Day Ring Volume & Night Ring Volume Setting

The ring volume for day time and night time can be set 
individually, 6:00 AM~18:00 PM is the day time by 
default,if you don't want to be disturbed at night,you 
can set the night ring volume to 0.
Select 

User Setup

 item on main menu page to enter 

setup page,then select 

Next Page 

item to enter User 

Setup 2 page, select Day 

Ring Volume Setting 

or

 

Night Ring Volume 

item.  then press ▲ / ▼ button to 

increase / decrease the value;  After finish, press Menu 
buton to save and exit.(press   button to cancel the setting and 
return last page)

Night Ring Volume

Current :         05

Cancel

Save&Exit

Select Item

Day Ring Volume

Current :         05

Cancel

Save&Exit

Select Item

User Setup 2

Day Ring Volume Setup ...
Night Ring Volume Setup ...
Monitor Time Setup ...
Restore to Default ...
Last Page

Exit

OK

Select Item

- 3 -

Summary of Contents for C5-AT25/D4

Page 1: ...English VIDEO INTERCOM SYSTEM USER MANUAL MENU TALK MONITOR Main Menu Monitor Intercom Alarm Function User Setup Close About OK Select Item C5 AT25 D4 Version 1 0 120313 ...

Page 2: ......

Page 3: ...reen MENU Button MONITOR Button UNLOCK Button LED Indicator CALL Button TALK Button Speaker Navigation Button Mounting Hook Main Connection Port Mounting Hook 145 160 cm 1 Fix 2 screws to the wall at a appropriate height 2 Connect the system correctly 3 Attach the monitor to the bracket ...

Page 4: ...alk with the Door Station during monitoring and press UNLOCK to open the door this function is depended on the system configuration 2 Operation Instructions 3 Image and Volume Adjustment During monitoring or talking press MENU Button the ADJUST MENU will be displayed Use Button to select the adjustment item use Button to decrease increase the value 1 The first item is Scene mode selection Total 4 ...

Page 5: ...p 1 Door Station Call Tone Intercom Call Tone DoorBell Call Tone Date Time Setup Next Page Exit OK Select Item 5 Day Ring Volume Night Ring Volume Setting The ring volume for day time and night time can be set individually 6 00 AM 18 00 PM is the day time by default if you don t want to be disturbed at night you can set the night ring volume to 0 Select User Setup item on main menu page to enter s...

Page 6: ...When the monitor is in standby mode press CALL Button to enter Intercom Function page or select Intercom item on main menu page Press Button to move upward downward to select the item you want press MENU Button to enter 1 Choose Alarm to Guard Unit item the monitor will send the alarm message to the guard center and show emergency calling 2 Choose Direct Call Guard Unit item the monitor dails the ...

Page 7: ... out alarm sound and sent the alarm signal to the guard center Infrared Sensor Delay sensor can be placed on living room or bedrooms When the sensor is set if some body invade into the defence area the monitor will sent out alarm sound and sent the alarm signal to the guard center You can set this sensor when nobody at home Smoke Sensor 24 hour sensor this sensor is opened by the system by default...

Page 8: ...rmed Alarm 8 Exit 3 Out Delay Period after you arm the system you will get into Out Delay Period monitor will sent out short Di every 3 seconds you will hear a long Di at the end of the Out Delay Period and the system is gotten into the protecting status By default the Out Delay Period is 40 seconds users must get out off the room within 40 seconds otherwise the system will treat the user as a inv...

Page 9: ...ame result as enter Main Menu Alarm Functions menu select Disarm item D Button Use this button to release the door same result as press the Unlock button on monitor 1 Remote control distance is normally up to 30 meters and will extend if the built in telescopic antenna is taken out 2 If the controlled distance is becoming shorter or LED doesn t light on while pressing any button open the remote co...

Page 10: ...unpredictable damage 1 Don t attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer servicing to qualified service personnel 2 To prevent fire or shock hazard do not expose this product to rain or moisture 3 Do not install the product where it is exposed to constant sunlight or rain 4 Do not install the product where excess...

Page 11: ......

Page 12: ...Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice ...

Reviews: