WIRING CONNECTION
1.PV connection
Select PV modules with excellent function and reliable quality. Open-circuit voltage of
module arrays connected in series should be <Max. DC input voltage; operating voltage
should be conformed to MPPT voltage range.
Max.DC Voltage Limitation
STEP 2
Warning!
PV module voltage is very high, which already achieve dangerous voltage range,
please comply with electric safety rules when connecting.
Please do not make PV positive or negative ground!
Note!
The following requirements of PV modules need to be applied for each input area;
Please do not make PV positive or negative ground!
In order to save cable and reduce the DC loss, we suggest to install the inverter
near PV modules.
Model
VT-6608303
Max. DC Voltage (V)
1000
MPPT Voltage Range (V)
125-500