background image

S718 Elf

User Manual

Summary of Contents for S718 Elf

Page 1: ...S718 Elf User Manual ...

Page 2: ... least 50cm from adjacent surfaces Be sure that no ventilation slots is blocked otherwise the unit will be overheated Before operation ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product s specification label It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambi...

Page 3: ...ion Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation Always install a safety cable that can hold at least 12 times the weight of the fixture when installing DO install and operate by qualified operator It must be installed in a place where there is out of the reach of people 2 INSTALLATIONS installations Note In order to increase pro...

Page 4: ...passes through the center hole of the bracket to fix it As an additional safety measure make sure to use at least one safety cable integrated in the base assembly to connect at least one appropriately rated safety cable to the fixture 3 DMX 512 control connections Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the ...

Page 5: ...ttings press the ENTER button to confirm use the UP DOWN button to select DMX Address press the ENTER button to confirm the present address will blink in the display use the UP DOWN button to adjust the address from 001 to 512 press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Please refer to the following diagram to addres...

Page 6: ...Channel MODE UNIT1 ADDERSS UNIT2 ADDERSS UNIT3 ADDERSS UNIT4 ADDERSS 17CH 1 18 35 52 5 Fixture size 6 Illuminance chart ...

Page 7: ...7 Effect Wheels STATIC GOBO WHEEL COLOR WHLLE Rotation GOBO ...

Page 8: ...ed in both directions Frost filter with smooth wash effect DMX Channel 17CH Operate mode DMX512 self propelled master slave Sound active RDM Fixture size 303 226 394mm Net weight 14 KG Features 1 Electric focuing system with 0 100 smooth dimming 2 Overheating self energy protection can extending lamp life 3 Three phase Motor with SY Brand XY axis magnetic coding positioning is m ore accurate 4 Wit...

Page 9: ...e press the menu key one or more times to return to the main interface 2 In the main interface press the Up key or the Down key to select the Settings button 3 Press the OK button to enter the Settings interface 4 In the Settings interface press the Up key or the Down key to select DMX Address 5 Press the OK key to enter the editing state 6 Press the Up key or Down key to modify the DMX address co...

Page 10: ...editing state Motor reset close open Lamp reset channel mode Standard 17CH Standard 17 channel mode X reverse close open Y reversal close open XY swap close open Swap the channels of the XY axes including fine tuning XY encoder open Use the encoder optical coupler to judge the out of step and automatically correct the position close Correct position without encoder optocoupler DMX signal Keep Cont...

Page 11: ...alue Y coded step value reset calibration X axis After entering the sub interface you can adjust the reset position of the X axis Y axis and other motors to make up for the error in the hardware installation The adjustment range is 128 127 and 0 means no adjustment Y axis color pattern glass pattern focusing enlarge Prism frost 10 4system Option Description DIS Dashboard software version MT Motor ...

Page 12: ...led There is a problem with the Y axis photoelectric switch or the Y axis motor or motor board X axis Hall error X axis Hall or there is a problem with the motor board Y axis Hall error Y axis Hall or there is a problem with the motor board Color wheel reset failed The color wheel Hall or the color wheel motor has a problem Pattern disk reset failed Gobo Hall or gobo motor is faulty Focus reset fa...

Page 13: ...w Forward flow from slow to fast 9 Static Gobo 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 191 192 255 Static Gobo1 white light Static Gobo2 Static Gobo3 Static Gobo4 Static Gobo5 Static Gobo6 Static Gobo7 Static Gobo8 Static Gobo1shock from slow to fast Static Gobo2shock from slow to fast Static Gobo3shock fro...

Page 14: ...tment Prism rotating forward flow Prism rotation reverse flow 15 focusing 000 255 gobo clarity from far to near 16 enlarge 000 127 128 255 no effect zoom in 17 reset 000 127 128 255 None there is no action for the area without the specified function Reset all motors 11 Common malfunctions 1 After the lamp is reset normally it will not accept the control of the console Check whether the digital sta...

Page 15: ...ase check whether the wires and connectors inside the lamp are detached or loose Check whether the electronic components of lamps such as electronic transformers PCB boards motor control boards etc are loose short circuited and burned out 3 When working the X axis or Y axis of the lamp does not move normally Check whether the transmission belt corresponding to the X and Y axis directions in the la...

Reviews: