Add a signal amplifier;
The signal line adopts high-quality shielded twisted pair;
Connect a signal terminating resistor (120 ohms) at the end of the fixture.
2. The lamps cannot be started
Check that the lamps have poor contact or fall off due to extrusion
deformation, vibration of internal parts, moisture and other reasons during
long-distance transportation.
Please check whether the wires and connectors inside the lamp are
detached or loose.
Check whether the electronic components of lamps (such as electronic
transformers, PCB boards, motor control boards, etc.) are loose,
short-circuited and burned out.
3. When working, the X-axis or Y-axis of the lamp does not move normally
Check whether the transmission belt corresponding to the X and Y axis
directions in the lamp is off and broken;
Check whether the data feedback receiver (optical coupler) corresponding
to the X and Y directions in the lamp is damaged;
Reboot to reset once.