The user manual is meant to ensure that the pre-separator is not handled and operated in an unsafe manner, 
and that the user/operator has no concerns or insecurity regarding the use of the appliance. The user manual 
must be kept near the pre-separator. 
 
If any questions occur regarding the operation or the collected material, the work must be stopped until all 
questions have been clarified. 
 
Pictures and drawings used in this manual are only for illustrative purposes, to make the understanding easier.  
The pictures and drawings can therefor differ from the actual product.  

 
 

Safety Precautions

 

 

 

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety. 
Children should be supervised to ensure that they do not play with the appliance. 

 

 

The machine is 

NOT

 approved for and must 

NOT

 be used for collection of flammable, explosive, poisonous 

or other dust, fluids or gasses that are extremely hazardous to health. 
 

 

The user must ensure that the appliance is adjusted to the task and that regulatory requirements are met. 

 

 

When collecting dust hazardous to health you must use a collection bag, and disposal must comply with the 
legal requirements for material (closed container, plastic bag etc.). 

 

 

Do 

NOT

 lift the pre-separator by the cyclone or the plastic parts fitted onto it. 

Use the lifting handles

 

 

Before use

 operators should be provided with information, instruction and training for the use of the 

appliance and the substances for which it is to be used, including the safe method of removal and disposal 
of the material collected. 

 

 

For user servicing, the appliance must be dismantled, cleaned and serviced, as far as is reasonably 
practicable, without causing risk to the maintenance staff and others. Suitable precautions include 
decontamination before dismantling, provision for local filtered exhaust ventilation where the appliance is 
dismantled, cleaning of the maintenance area and suitable personal protection. 
 

 

When carrying out service or repair operations, all contaminated items, which cannot be satisfactorily 
cleaned, are to be disposed of. Such items shall be disposed of in impervious bags in accordance with any 
current regulation of the disposal of such waste. 

 
If any doubt regarding the safe use for the equipment – please contact the place of purchase.  

 
IMPORTANT! Never vacuum hot or glowing material. 
 
IMPORTANT!  Do not extract directly from a spark generating process.  

Summary of Contents for RONDA CF-502 Series

Page 1: ...Til opsamling af st rre m ngder st v 05 2018 F r Auffangen von gr eren Mengen von Staub For Collection of large amounts of dust NB L s brugsanvisningen inden maskinen tages i brug Die Betriebsanleitun...

Page 2: ...RONDA CF 502 RONDA CF 502 2 V BR NDUM A S...

Page 3: ...RONDA CF 502 RONDA CF 502 3 V BR NDUM A S SIDE 5 Dansk SEITE 11 Deutsch PAGE 17 English...

Page 4: ...RONDA CF 502 RONDA CF 502 4 V BR NDUM A S...

Page 5: ...de som t rre RONDA CF 502 opsamler materialet direkte i en kraftig opsamlingspose plastik som forsegles med tilh rende lukkestrips Herved sikres nem og forsvarlig t mning og transport af det opsamlede...

Page 6: ...t v skal der anvendes opsamlingspose bortskaffelse skal ske i henhold til g ldende krav for materiale lukket container plastiks k etc Forudskilleren m IKKE l ftes i cyklonen eller plastdele monteret p...

Page 7: ...lderen direkte til sugeslangen til st vsugeren fig 2 Forudskilleren m IKKE l ftes i cyklonen eller plastdele monteret p denne skal l ftes i h ndtagene Opbygning og beskrivelse Opsamlingsbeholder Opsam...

Page 8: ...udtages HUSK Bortskaffelse af sundhedsfarligt st v skal foreg i overensstemmelse med g ldende regler L g en ny opsamlingspose i opsamlingsbeholderen S t toppen p plads og monter r r stykkerne Opsamli...

Page 9: ...t klud Fejlfinding Hvis maskinen ikke suger tilfredsstillende Sugeslange r r eller mundstykke kan v re blokeret Stop maskinen og fjern blokeringen Opsamlingsbeholderen eller opsamlingsposen kan v re o...

Page 10: ...ldelse kan ikke henf res hertil Reparation har ikke v ret fors gt udf rt af andre end V BR NDUM A S eller servicev rksteder godkendt af V BR NDUM A S til garantireparationer Serviceydelser uden beregn...

Page 11: ...CF 502 f ngt das Material direkt in einem kr ftigen Auffangbeutel Kunststoff auf der mit angeh rendem Kabelbinder versiegelt wird Hierdurch wird eine einfache und sichere Leerung und auch einfacher un...

Page 12: ...ufsaugen von gesundheitsgef hrdendem Staub muss Auffangbeutel verwendet werden Die Entsorgung muss in bereinstimmung mit den g ltigen Bestimmungen f r solchen Abfall erfolgen geschlossener Container K...

Page 13: ...direkt aus dem Beh lter in den Vakuumschlauch des Staubsaugers gesaugt wird Fig 2 Der Vorabscheider NICHT am Zyklon oder darauf montierte Kunststoffteile heben Tragegriffe nutzen Aufbau und Beschreibu...

Page 14: ...UNG Entsorgung gesundheitsgef hrlichen Staubes muss nach den geltenden Regeln stattfinden Einen neuen Auffangbeutel im Auffangbeh lter anbringen Den Oberteil an seinem Platz anbringen und die Rohrst c...

Page 15: ...ieden stellendes Saugergebnis liefert Saugschlauch Rohr oder D se k nnen blockiert sein Die Maschine ausschalten und die Blockierung entfernen Der Auffangbeh lter oder der Auffangbeutel kann berf llt...

Page 16: ...on ausgenommen dass nicht von anderer Seite als von V BR NDUM A S oder der von V BR NDUM A S zugelassenen Vertragswerkst tten versucht wurde diese als Garantiereparatur durchzuf hren Serviceleistungen...

Page 17: ...ed materials wet dry damp and dry dusts RONDA CF 502 collects the material directly into a strong collection bag plastic which can be sealed with the cable tie This design ensures a minimum of dust re...

Page 18: ...s adjusted to the task and that regulatory requirements are met When collecting dust hazardous to health you must use a collection bag and disposal must comply with the legal requirements for material...

Page 19: ...ot sucked directly into the suction hose of the vacuum cleaner fig 2 Do not lift the pre separator at the cyclone top or the plastic parts fitted onto it Use the lifting handles Description The collec...

Page 20: ...of REMEMBER Disposal of dust hazardous to health must take place in accordance with the national regulations Install a new collection bag in the collection container Replace the top and re install the...

Page 21: ...ry or moist cloth Fault finding If the pre separator is not delivering full suction The suction hose tube or nozzle may be blocked Stop the machine and remove the blocking The collection container or...

Page 22: ...are not covered by the warranty No repair attempts have been made by parties other than V BR NDUM A S or authorized service centres approved by V BR NDUM A S Service and repair free of charge include...

Reviews: