V. BRØNDUM A/S RONDA 1800H TWIN User Manual Download Page 9

USER MANUAL

 

 
 

 

 

V. BRØNDUM A/S

 

  

RONDA

 1800H TWIN   

ENG - 9 

 

Applications

 

 

 

RONDA

 1800H TWIN is a vacuum cleaner in accordance with DS/EN 60335-2-2 and CEI/IEC 60335-2-69 

Annex AA class H and may only be used as such. 

 
RONDA

 1800H TWIN may be used for collection of dust hazardous to health according to CEI/IEC 60335-2-69 

Annex AA dust class 

H

 
RONDA

 1800H TWIN may 

not

 be used for collection of fluids or moist dust. 

 
RONDA

 1800H TWIN may 

not

 be used for collection of flammable, explosive, poisonous or extremely health-

hazardous dust, fluids or gasses. 
 
RONDA

 1800H TWIN may only be used in dry environments and may not be used or stored outdoors or indoors 

under wet conditions. 
 

The capacity of a vacuum cleaner to suck vacuum depends on the air. Theoretical the suction capacity will fall 
when the vacuum cleaner is used at altitudes. The suction capacity of the vacuum cleaner will be constant from 0 
to approx. 800 m above sea level. From 800 to 2000 m the suction capacity will theoretically fall to approx. 75%. It 
is not recommended to use the vacuum cleaner at more than 2000 m above sea level, as the cooling and the 

suction capacity will be considerably reduced. 

 

 

 

 

Description of the Main Parts

  

 
RONDA

 1800H TWIN is designed as a handy and compact industrial vacuum cleaner for collection of fine dust 

and dust hazardous to health. 

 

 

Motor Top with Suction Motor and HEPA Filter 

 

The motor top is equipped with two bypass suction motors and switches for the suction 
motors as well as for choice of hose diameter (Ø38mm and Ø50mm). 
 

The powerful suction motors are equipped with non-return valves for operation with one 
motor.  
 
 

 
 
The motor top is fitted with a HEPA filter - dust class “H”. 
 

The filter holds back the fine and smallest dust particles, which have not been held 
back by the multi-tube filter. The filter holds back the particles larger than 0.3 

(0.0003 mm). The surface of the filter is 1.1 m

2

 

 
 

 

Summary of Contents for RONDA 1800H TWIN

Page 1: ...04 24 RONDA 1800H Twin With Longopac or collection container Handy Industrial Vacuum Cleaner for Fine and Hazardous Dust IMPORTANT Use only for dry dust Read this manual before you start using the va...

Page 2: ...USER MANUAL V BR NDUM A S RONDA 1800H TWIN ENG 2...

Page 3: ...e Filter 10 Collection Container and Collection Bag 10 Mounting the hose 11 Mode of operation 12 Assembling 13 Collection of Dry Dust 14 Cleaning the Multi Tube Filter during Operation 15 Emptying 16...

Page 4: ...ndustry and the construction industry today The machine is ideal for the collection of fine and health hazardous dust such as cement or dust from grinding machines The machine is ideal for use in conn...

Page 5: ...used as a dust extractor on power tools you must ALWAYS turn off the tool before you turn off the vacuum cleaner IMPORTANT The motor top must not be covered when the vacuum cleaner is in use Please re...

Page 6: ...n a risk of fingers being caught may occur The handle is manually operated and is activated by human power alone In terms of design the best solutions have been sought to minimize and eliminate this r...

Page 7: ...Noise Machine pressure level uncertainty KpA 3dB Measured only as machine Sound power level LWA uncertainty KpA 3dB Measured with hose pipes and floor accessory Vibration 230 1350 1200 2700 2400 2700...

Page 8: ...y nozzles You can reorder the accessories using the following product numbers 1 50 mm professional s set 80 33 5027 2 Plastic hose antistatic 5 m 84 54 5022 3 Straight tube with bend 80 52 5000 4 Meta...

Page 9: ...ity of the vacuum cleaner will be constant from 0 to approx 800 m above sea level From 800 to 2000 m the suction capacity will theoretically fall to approx 75 It is not recommended to use the vacuum c...

Page 10: ...NDA 1800H TWIN LP CT The CT models are equipped with a collection container which is mounted under the machine Empty the machine by lowering the container and driving it underneath the machine Inside...

Page 11: ...ipped with a plug which is to be used during transport and whenever the machine is not in use Insert the hose coupling in the machine and turn to the right to lock When the coupling is mounted the sma...

Page 12: ...icles will be held back in the collection bag and or the multi tube filter The air flow and the remaining particles which have not fallen to the bottom of the collection container or have been held ba...

Page 13: ...been correctly mounted in the collection container Inspect the filters of the machine and make sure that they are intact and undamaged see the chapter Change of Filters If dust hazardous to health is...

Page 14: ...diameter must therefore be set by means of the hose selection switch O 38mm I 50mm This alarm must be tested before use Block the intake at the end of the hose and the machine will start beeping Unblo...

Page 15: ...tube filter It is recommended always to leave the machine for a few minutes before emptying it if the machine is being used without collection bag The dust will fall to the bottom of the container an...

Page 16: ...n the bag Attach two cable ties with approx 10 cm distance onto the bag Cut the bag between the two cable ties Fold back the end of the bag and attach another cable tie to secure the closure Perform t...

Page 17: ...th cover Plastic bag min 100 m or bags with equivalent tensile strength of the plastic material Collection of dust hazardous to health must always take place into a collection bag The collection bag m...

Page 18: ...al damages Check maintenance of the machine Description Before after use Month year Hours Check replacement of motor 700 Check of HEPA filter and machine Yearly Emptying and cleaning After use as requ...

Page 19: ...st and will rapidly be blocked if the multi tube filter is damaged Loosen the container clips of the motor top and remove the motor top Place the motor top on a dry clean and flat surface Inspect the...

Page 20: ...t washer and seal These are to be used again Pull a plastic bag 100 m or the like over the filter Pull off the filter from the bracket so the O ring and the base are released Remove the O ring and bas...

Page 21: ...ed out by the local environmental authorities How to mount the new HEPA filter Apply some moisture or lubricant to the O ring before mounting Push the filter down over the bracket until it is on the a...

Page 22: ...tor top Start the machine and block the suction hose Normally you can hear a possible leak Loosen the container clips of the motor top place the motor top correctly and lock the clips again The multi...

Page 23: ...T has been designed and produced in conformity with the basic requirements and other relevant conditions of the following directives Machine Directive Directive 2006 42 EU EMC Directive Directive 2014...

Page 24: ...nsufficient maintenance is not covered by the guarantee No repair attempts have been made by others than V BR NDUM A S or service centres approved by V BR NDUM A S to carry out guarantee repairs Servi...

Reviews: