12
- Minimum input current: 30mA DC or AC(rms)
- Maximum input current: 10A DC or AC(rms)
When the measured current is greater than 5A, the continuous measurement time is not longer
than 15 seconds, after the measurement to stop the current measurement for more than 1
minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
3.2.6 Resistance
Range
Resolution
Accuracy
600Ω
0.1Ω
(
0.8% re 3 digits
)
6kΩ
0.001k
Ω
60kΩ
0.01kΩ
600kΩ
0.1kΩ
6MΩ
0.001M
Ω
(
1.2% re 3 digits
)
20
MΩ
0.01M
Ω
(
2.0% re 5 digits
)
- Overload protection: AC/DC 250V
3.2.7
Line off test
Range
Resolution
Function
0. 1W
If the measured resistance is less
than 50W, the buzzer inside the
instrument may sound or may not
sound. Less than 10W will be
pronounced
- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)