![UWT Vibranivo VN 4000 Series Technical Information/Instruction Manual Download Page 17](http://html1.mh-extra.com/html/uwt/vibranivo-vn-4000-series/vibranivo-vn-4000-series_technical-information-instruction-manual_1066148017.webp)
Level limit switch
Series VN 4000
Technical Information / Instruction manual
page G
Notes for use in Hazardous Locations
Max. Surface Temperature and Temperature Class
The temperature marking on the type plate refers to the instruction manual.
In the following table the relevant temperature ratings are shown.
The maximum surface temperature (resp. temperature class) is the warmest temperature of the unit which could occur during
malfunction (according to Ex-definition)..
process
side
ambient side
Max.
ambient
temperature
Max. process
temperature
Max. surface
temperature
Temperature
class
(Division System)
Temperature
class
(Zone System)
60°C (140°F)
110°C (230°F)
115°C (239°F)
T4A
T4
120°C (248°F)
120°C (248°F)
T4A
T4
130°C (266°F)
130°C (266°F)
T4
T4
140°C (284°F)
140°C (284°F)
T3C
T3
150°C (302°F)
150°C (302°F)
T3C
T3
Vibranivo
®
1
2
3
4
5
6
7
8
9
10
11
12
VN 4000 a
gi161213
17